Determining the mode of operation of the system section, taking into account the current topology and predictive analysis of the active-adaptive network of 6-10 kV
1
Don State Technical University, Don Engineering Center, 344000, Rostov-on-Don, Russia
2
«AC ЕnergyCom» LLC, 344000 Rostov-on-Don, Russia
3
«Rosseti» PJSC, Rostov enterprise of main electric networks, 344000, Rostov-on-Don, Russia
* Corresponding author: yurov_dstu@rambler.ru
Technical solutions aimed at improving the reliability of power supply to consumers of the 6-10 kV network are proposed, a block diagram of a fundamentally new device for diagnosing and protecting cells of 6-10 kV power cable lines with a single algorithm of operation is shown, which allows simultaneously performing current protection of the controlled feeder and monitoring with a predictive assessment (residual resource) of the state of the cable insulation material. A possible scheme of interaction of elements of an active-adaptive power unit of 6-10 kV is shown on the example of a cell of a 6-10 kV cable line. he device will allow you to control leakage currents in distribution networks, taking into account the remaining cable life, reduce insulation losses during power transmission and increase the energy efficiency of the controlled network by reducing power interruptions to the consumer. The quantitative values of the device will be determined after its introduction into trial operation.
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.