Issue |
E3S Web Conf.
Volume 429, 2023
The Third International Conference of Construction, Infrastructure, and Materials (ICCIM 2023)
|
|
---|---|---|
Article Number | 04022 | |
Number of page(s) | 6 | |
Section | Geotechnical & Earth Sciences | |
DOI | https://doi.org/10.1051/e3sconf/202342904022 | |
Published online | 20 September 2023 |
Designing a drilled pile foundation in a dual system structure
1 Department of Civil Engineering, Universitas Kristen Maranatha, Jl. Surya Sumantri No.65, Bandung City 40164, Indonesia
2 Department of Computer Engineering, Universitas Kristen Maranatha, Jl. Surya Sumantri No.65, Bandung City 40164, Indonesia
3 Department of Electrical Engineering, Universitas Kristen Maranatha, Jl. Surya Sumantri No.65, Bandung City 40164, Indonesia
* Corresponding author: daud.rw@eng.maranatha.edu
Drilled pile foundations that have been set in hard soil are generally used for buildings with shear walls. By nature, a drilled pile foundation can withstand moments because of the drilled pile’s dimensions and the amount of reinforcement installed. This study presents a structural analysis of a 10-story building supported by a dual system structure to meet earthquake requirements. The results show that, by using a dual system, the earthquake requirements (natural period, modal, story shear, story drift, and P-Delta) are met. Other results show that the base shear force of the shear wall has a value of 58.76% for the X-direction and 63.72% for the Y-direction. The base shear force value of the frame is 41.23% for the X-direction and 36.27% for the Y-direction. Therefore, the requirements of the dual system are met because the resisted base shear force of the frame is higher than 25%. The dual system provides a normal force value of 24.32% for the shear wall, while the frame carries 75.67%. The bearing capacity of the drilled pile with a safety factor = 2.5 is 162 tons for a diameter of 50 cm, 214 tons for a diameter of 60 cm, 340 tons for a diameter of 80 cm, 493 tons for a diameter of 100 cm, 672 tons for a diameter of 120 cm, and 993 tons for a diameter of 150 cm. The result of the pile driving analyzer test values for a 120 cm diameter range from 988 to 1,232 tons.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.