Issue |
E3S Web Conf.
Volume 431, 2023
XI International Scientific and Practical Conference Innovative Technologies in Environmental Science and Education (ITSE-2023)
|
|
---|---|---|
Article Number | 06019 | |
Number of page(s) | 9 | |
Section | Industrial Innovation and Decarbonization | |
DOI | https://doi.org/10.1051/e3sconf/202343106019 | |
Published online | 13 October 2023 |
About the choice of the test method to clarify the actual working scheme of the beam
Moscow State University of Civil Engineering, Yaroslavskoye shosse, 26, Moscow, 129337, Russia
* Corresponding author: PerunovAS@gic.mgsu.ru
This article discusses the problem of determining the actual scheme of a precast reinforced concrete frame of a building when performing engineering surveys. The method of connecting precast reinforced concrete structures in industrial buildings with heavy equipment plays an important role in assessing the stress state of building structures. It is not always possible to perform the opening of nodes in the conditions of existing production, since this requires stopping technological processes or dismantling equipment. The article discusses the possibilities of static and dynamic tests for the study of support units in precast reinforced concrete structures during engineering surveys. The possibilities of static and dynamic test methods are considered, as well as the advantages and disadvantages of these methods when evaluating support units in precast reinforced concrete structures of buildings and structures during surveys. As an example for the study, the case of determining the current structural scheme of a precast reinforced concrete floor using dynamic tests is considered. The article analyzes previous studies on the use of the dynamic method in determining the actual scheme of existing reinforced concrete structures of an industrial building. The results of theoretical studies and their comparison with experimental results are presented. The general conclusions based on the results of the study are formulated, and recommendations are given on the choice of a method of testing structures for cases of establishing a structural scheme of precast reinforced concrete crossbars in operated industrial buildings during survey work.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.