Liquid air filtration and continuous monitoring: Customized indoor air quality
1 Veltha Despoluição Atmosférica Rio Janeiro, Brazil.
2 3 R Brasil – Rio de Janeiro, Brazil.
Air treatment in environmental air conditioning systems exposes the system to gases, contaminants, and often biological pollutants that cannot be solved by traditional mechanical filtration, motivating decision-makers to diagnose challenges and develop innovative strategies to mitigate the problem. More and more, in environments with high turnover of people (e.g., hospitals, hotels and shopping centers), fresh air ventilations are avoided and replaced by closed windows air purifier solutions to account for undesirable saturation of the atmosphere and the presence of pollutants such as PM10, PM2.5, PM1.0, nitrogen, and carbon oxides. The consensus is that polluting gases render the most efficient traditional filters ineffective. The ANSI/ASHRAE 62.1 and EN13779 standards reveal the absence of air treatment technologies that use the wet route in air conditioning systems. This work discusses the liquid air multi-venturi centrifugation technology of hydrodynamic precipitator purifiers in association with the synchronized and continuous monitoring of parameters (PM10, PM2.5, PM1.0, CO2) in the external urban environment and internal environments of a shopping center. It evaluates the performance of the wet route for the physical-chemical and biological treatment of air. Efficiency for retaining particulate matter in a single step without disposable filter reached levels above F9 (85-95% PM2.5), with a reduction of 82.4% for CO2. Wet route technology extends the air conditioner’s life, reducing external air flows and energy consumption by up to 13%, making IAQ a manageable and customizable variable. Among the conclusion of the investigation, the authors believe that the migration of industrial pollutant control technologies, such as liquid filtration promoted by gas scrubbers and hydrodynamic precipitators, should be considered as a first choice option due to the high efficiency achieved in the three types of pollutants to be controlled. That is micrometric particulate matter such as anthropogenic PM1.0 capable of reaching the lung alveoli, chemicals such as carbon dioxide and nitrogen, and biological assets such as viruses and bacteria that showed the vulnerability of HVAC-R systems during the COVID pandemic that rendered windowless corporate buildings unusable.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.