| Issue |
E3S Web Conf.
Volume 687, 2026
The 2nd International Conference on Applied Sciences and Smart Technologies (InCASST 2025)
|
|
|---|---|---|
| Article Number | 02006 | |
| Number of page(s) | 10 | |
| Section | Green Technologies & Digital Society | |
| DOI | https://doi.org/10.1051/e3sconf/202668702006 | |
| Published online | 15 January 2026 | |
Occupancy-Aware Spatio-Temporal Building Energy Forecasting with a Hybrid Long ShortTerm Memory and Graph Neural Network Benchmark Using Public Datasets
1 Information Systems, Universitas Pignatelli Triputra, Surakarta, Indonesia
2 Informatics, Universitas Sanata Dharma, Yogyakarta, Indonesia
3 Software Engineering, Universitas Pignatelli Triputra, Surakarta, Indonesia
* Corresponding author: This email address is being protected from spambots. You need JavaScript enabled to view it.
Abstract
Accurate short-term forecasting of building energy demand is complicated by coupled temporal dynamics, cross-meter spatial effects, and occupancy-driven variability. We present an occupancy-aware spatiotemporal framework that uses a Long Short-Term Memory (LSTM) branch and a Graph Neural Network (GNN) branch, augmented with calibrated occupancy probabilities transferred from labeled sources to public corpora lacking occupancy labels. Using BDG2 and ASHRAE GEPIII, we construct physical, correlation kNN, and learned kNN graphs; engineer calendar– weather–lag/rolling features; and evaluate with forward-chaining splits across horizons t+1…t+24. Primary (MAE, RMSE, MAPE) and domain metrics (CVRMSE, NMBE) follow ASHRAE Guideline 14. The hybrid attains RMSE 2.766 kWh (BDG2) and 2.740 kWh (ASHRAE GEPIII), yielding 33.44% and 33.52% reductions versus a ridge/XGBoost baseline, and statistical parity with LSTM-only (ΔRMSE −0.23% on BDG2; +0.02% on ASHRAE GEPIII; paired tests p<0.05). Horizon-wise curves show stable gains—especially during business hours—and learned kNN typically provides the lowest average error. Per-meter distributions indicate 100% of meters satisfy CVRMSE ≤ 30% and ∣NMBE∣ ≤ 10%, supporting calibration and retro-commissioning use. These findings demonstrate that using temporal and graph-based spatial cues with transferable occupancy signals delivers robust, label-efficient multi-meter forecasting, with units standardized (kWh, °C) and |NMBE| consistently denoted for clarity.
© The Authors, published by EDP Sciences, 2026
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.

