Issue |
E3S Web Conf.
Volume 111, 2019
CLIMA 2019 Congress
|
|
---|---|---|
Article Number | 01092 | |
Number of page(s) | 7 | |
Section | Advanced HVAC&R&S Technology | |
DOI | https://doi.org/10.1051/e3sconf/201911101092 | |
Published online | 13 August 2019 |
Analysis of Backward and Forward Effects on a Grooved Co-axial Heat Exchanger by Response Surface Methodology
1 İzmir Katip Çelebi University, Faculty of Engineering and Architecture, Department of Mechanical Engineering, İZMİR
2 İzmir Katip Çelebi University, Graduate School of Natural and Applied Sciences, İZMİR
* Corresponding author: sahin.gungor@ikc.edu.tr
In the literature, it is proved that grooved pipe models are thermally more efficient than the smooth pipe model. Different than the previous studies in which the groove dimensions are constant along the pipe, we study the effect of groove radius and the gap between adjacent grooves on the local heat transfer coefficients using computational fluid dynamics software. The grooved section consists of three sub-sections to see the effects of groove dimension in stream-wise flow direction. We vary the radius of circular grooves parametrically in each section to optimize the local groove radius throughout the pipe. We couple the fluid flow (1200<Re<24000) with energy equations, and the grooved sections are set as heated wall at constant temperature of 350 K. The optimal mesh has been selected by performing mesh independence study and finer mesh has been used in heated wall section. The radii of grooves are varied from 2 to 6 mm with an increment of 0.2 mm considering the manufacturability of the pipe, to do so we use the design of experiments (DOE). All DOE tools in ANSYS software are examined and compared with full factorial results. After DOE process, local heat transfer coefficient values of all groove parts are examined by response surface methodology (RSM).
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.