Exhaled air speed measurements of respiratory air flow, generated by ten different human subjects, under uncontrolled conditions
Technical University – Sofia, FPEPM, Department:” Hydroaerodynamics and Hydraulic Machines”, Sofia, 1000, Bulgaria
The presented study reveals a multi-point experimental measurement of the airflow speed, generated in the exhalation phase from the human respiratory cycle, based on data from 10 real human subjects. The results obtained demonstrate the exceptional irregularity and the transient character of the human respiratory cycle, in terms of measured speed at different points of man-generated exhalation air flow. The presented exponential trend lines show as expected, that there is a reduction in the exhalation speed, with the increase of the distance from the nose.
The summary analysis shows that at 10 cm distance from the nose the maximum as well as the average measured speeds are higher than the one, measured at 5 cm distance. This suggests that due to the physiology of the human nose, 5 cm distance is not enough to characterize the fully developed exhalation jet flow. It is suggested that at this distance the exhalation jets are still two, issuing from each nostril, with different flowrate ratio.
The obtained flow characteristics can be used to compare, validate and verify data from conducted numerical studies of the breathing process, via virtual models or real breathing thermal mannikins.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.