Numerical estimation of thermal load in a three blade vertically agitated mixer
Department of Applied Mechanics, IIT Madras,
Chennai,
India
* Corresponding author: arulk@iitm.ac.in
The objective of this study is to understand the flow physics and resulting heat transfer behind the mixing of highly viscous solid propellant in a vertical three blade mixer. The mixer comprises a four-winged central agitator rotating in the counter-clockwise direction and two other two-winged agitators rotating in clockwise direction. The temperature rises due to the shearing of the solid propellant. Uncontrolled temperature rise may result in the self-ignition of the propellant and other fire hazards. Thus it becomes important to quantify the heat generated due to viscous dissipation to attain a controlled atmosphere for mixing. A detailed CFD analysis is carried out, and two-dimensional energy equation with viscous dissipation term is solved to quantify the temperature rise due to viscous dissipation. The effect of angular velocity of the agitator and viscosity of the propellant over temperature rise is studied quantitatively using the overset method in OpenFOAM. The maximum velocity of the propellant is observed at the tip of agitators, whereas maximum temperature rise is found around the vicinity of the blade profile. A correlation is proposed to predict the temperature rise with time due to the viscous effect for the given range of angular velocity.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.