Use of radon barriers to reach an acceptable radon level
Department of Building Technology and Process, BUILD, Aalborg University, A.C. Meyers Vænge 15, 2450 Copenhagen S, Denmark
* Corresponding author: tvr@sbi.aau.dk
A method is presented for theoretically estimating the necessary airtightness of a radon barrier. Radon barriers are used to balance the indoor radon concentration. To balance radon at an acceptable level, for a given ventilation rate for indoor air, a barrier must fulfil the requirements for airtightness and the indoor-air radon penetration from the soil, which is determined by the radon concentration in the soil gas. The method identifies the optimal radon barrier for a building. Ten different radon barriers are evaluated. Barriers include system solutions based on materials such as bitumen-based radon blockers, wet-room membranes, reinforced fix mortar pastes, and polyethylene membranes. The barriers are tested using a modified version of the test method NBI 167/02 radon membrane: test of airtightness. The radon barriers are evaluated for a typical building construction for a single-family house with radon exposure from the ground. An acceptable radon concentration of 100 Bq/m3 in indoor air is used in combination with a number of higher radon levels. The different radon barriers are evaluated in accordance with their ability to prevent air penetration from the ground. Furthermore, how mounting a barrier can affect the durability of a building is discussed, as the measures may create a far more vulnerable building.
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.