Evaluating the value of synchrotron radiation phase-contrast CT imaging in the study of knee joint microstructure
School of Physics and Electronic Engineering, Yancheng Teachers University, Yancheng 224007, China
* Corresponding author: lclyctc@163.com
The knee joint is one of the tissues that often appear diseased, and the pathogenesis owing to its structure. Therefore, the micro-structure of the knee joint was studied by synchrotron radiation phasecontrast CT imaging (SRPCI-CT). The contrast and the sharpness of the reconstructed slice were calculated and analysed. From these results, the layer structure of the joint tissue can be seen. The cartilage layer (including the meniscus) is about 1.44 mm, and the epiphyseal layer is about 2.25 mm, which conforms to the actual situation of rat knees. From the 3D images, the structure of the meniscus and the epiphyseal bone can be observed. The epiphyseal bone line is also particularly obvious. Simultaneously, the epiphyseal bone also has a mesh structure, which has the characteristics of both cartilage and tibia. Further research on the tibia can determine that the trabecular bone line is about 130 microns. Finally, the bone volume fraction (BVF) of the joint, the data also reflect the existence of a layer structure, and its scale distribution is consistent with the results of sharpness and contrast analysis. The SRPCI-CT can play an important role in the study micro-structure of joints.
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.