Issue |
E3S Web Conf.
Volume 274, 2021
2nd International Scientific Conference on Socio-Technical Construction and Civil Engineering (STCCE – 2021)
|
|
---|---|---|
Article Number | 07002 | |
Number of page(s) | 9 | |
Section | Energy Efficiency and Thermal Protection of Buildings | |
DOI | https://doi.org/10.1051/e3sconf/202127407002 | |
Published online | 18 June 2021 |
Dew point temperature as overwetting indicator of enclosing structures
Kazan State University of Architecture and Engineering, 420043 Kazan, Russia
* Corresponding author: kuprivan@kgasu.ru
Overwetting of enclosing structures is a negative factor of their operation. Due to the fact that it reduces thermal protection, it causes the corrosion processes and leads to enclosing structures materials destruction on account of alternating freezing and thawing. Present investigations on the analysis of condensation of moisture vapor and moist condition of enclosing structures does not allow for definition of overwetting rate of enclosures in the preset climate. These questions are also not regulated in the current normative documents. Enclosing structures developed as a result of conservation of energy have unpredictable accumulation of condensation and overwetting rate under service conditions. The article examines a new concept «dew point temperature» that is a characteristic of construction solution of enclosing structures and used materials. The dew point temperature is numerically equal to external temperature at which we can observe condensation in-plane of maximum overwetting of enclosing structures for the first time. It was demonstrated that every construction solution of enclosure has its own dew point temperature, according to which the amount of condensation in identical climatic conditions will be formed. The result of investigation is the assumption about the introduction of a new characteristic called «dew point temperature of enclosing structure» into the scientific discourse and into the check-list of mandatory thermotechnical values of enclosing structures. The dew point temperature describes the capacity of construction solution of enclosure for overwetting in the preset climatic conditions.
Key words: condensation / overwetting / moisture vapor pressure / temperature / climate
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.