Assessment of Thermal Environment in a Kitchen with a New Ventilation System
1 School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China
2 Vanke real estate development co. ltd, Changsha Vanke, Hunan Province, 410000, China
3 School of Architecture, Harbin Institute of Technology, Heilongjiang Province, 150006, China
4 Department of Architecture, School of Design, Shanghai Jiaotong University, Shanghai, 200240, China
5 School of Mechanical Engineering, Purdue University, West Lafayette, IN, 47905, USA
* Corresponding author: yanchen@purdue.edu
Chinese kitchen environment is usually hot and humid in summer and cold in winter, while housewife spends considerable time there. This investigation developed a new ventilation system for Chinese kitchens to improve thermal comfort level. To assess the thermal performance of the ventilation system, 32 cooks were asked to prepare the same dishes in the kitchen with or without the system in summer in Changsha, China. The assessment was carried out by subjective questionnaire survey on thermal sensation vote (TSV) and objective on-site measurements of the indoor air temperature and cook’s skin temperature. The indoor air temperature was measured at different locations in the kitchen. The skin temperature was measured at 18 body parts of the cooks. The results show that the thermal environment in the kitchen was non-uniform and local thermal sensation had a great influence on the whole body sensation. Without the new ventilation system, the cooks complained that the hottest parts were thorax, head and face areas. Reasonably good correlation existed between the cooks’ skin temperatures and their thermal sensation votes. The increase of cooks’ skin temperature with the ventilation system was lower than that without the ventilation system. TSV was improved with the new ventilation system.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.