In order to solve the problems of protection misoperation and refusing to operate caused by the lack of measurement information in smart substation, a substation protection method which can effectively eliminate the influence of transformer inrush current and bus CT saturation when the measurement information of substation and bus connecting line is missing is proposed. Through the theoretical analysis of current synthesis method based on Kirchhoff current law, it is proved that transformer inrush current and bus CT saturation will lead to the misjudgment of differential protection. Accordingly a new method of station protection is proposed to deal with the lack of measurement information. In order to verify the correctness of the method, taking a typical 220kV substation model as an example, PSCAD / EMTDC electromagnetic transient simulation software is used to simulate and verify different conditions and different types of faults. The results show that the proposed protection method can accurately eliminate the interference of transformer inrush current and bus CT saturation, ensure the correct action of differential protection, and improve the stability of substation when the measurement information is missing.
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.