Issue |
E3S Web Conf.
Volume 271, 2021
2021 2nd International Academic Conference on Energy Conservation, Environmental Protection and Energy Science (ICEPE 2021)
|
|
---|---|---|
Article Number | 01032 | |
Number of page(s) | 4 | |
Section | Energy Development and Utilization and Energy Storage Technology Application | |
DOI | https://doi.org/10.1051/e3sconf/202127101032 | |
Published online | 15 June 2021 |
Conductivity Variation during Irreversible Electroporation
China Academy of Information and Communications Technology, Beijing, 100191, China
* Corresponding author: yanglei@caict.ac.cn
Irreversible electroporation (IRE) is an emerging tumour ablation technique, which utilizes non thermoelectric pulse to ablate tumours. Compared with the common tumour treatment methods, e.g., surgery, chemotherapy and radiotherapy, IRE has advantages of short action time, no massive bleeding of tissue during ablation, avoiding heat sink effect, etc. However, the process of IRE will be affected by the distribution of E-field of the tissue. The major factors which affect E-field distribution are parameters of the electrical pulse and characteristics of the tissue, e.g., the conductivity of the tissue. We utilized the finite element analysis software COMSOL Multiphysics 5.4 to calculate the variation in liver tissue conductivity during IRE. In this study, there is a Low-Voltage High-Frequency (LVHF) pulse involves 3500 unipolar and bipolar pulses, and a High-Voltage Low-Frequency (HVLF) pulse involves eight unipolar and bipolar pulses. The results show that the conductivity change of the HVLF pulse is higher than that of the LVHF pulse due to the higher strength of E-field. The most important conclusion is that the LVHF pulse can only change the tissue conductivity near the electrode tip. The HVLF pulse will significantly change the conductivity in the tissue between the electrodes.
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.