Issue |
E3S Web Conf.
Volume 271, 2021
2021 2nd International Academic Conference on Energy Conservation, Environmental Protection and Energy Science (ICEPE 2021)
|
|
---|---|---|
Article Number | 04038 | |
Number of page(s) | 4 | |
Section | Environmental Materials and Solid Waste Recycling Technology | |
DOI | https://doi.org/10.1051/e3sconf/202127104038 | |
Published online | 15 June 2021 |
Application Value of Bedside Ultrasound in the Positioning of PICC Tips in Preterm Infants
1 Yuting Jiao, Zhi Yang, Department of Ultrasound, Binzhou Medical University Hospital, Binzhou, 256600, China
2 Yumei Wu, Department of NICU, Binzhou Medical University Hospital, Binzhou, 256600, China
* Corresponding author: Zhi Yang, Email: 13061030808@163.com
Objective To investigate the application value of bedside ultrasound in the localization of the tip of a Peripherally Inserted Central Catheter (PICC) in preterm infants. Methods 52 preterm infants underwent bedside ultrasound and bedside X-ray examination. Observing the position of the catheter tip, and using the bedside X-ray positioning as the gold standard. Statistics of the incidence of PICC tip normal position and ectopic position showed by bedside ultrasound, and comparing the difference between the results of bedside ultrasound and bedside X-ray. Calculating the accuracy, sensitivity, and specificity of ultrasound in diagnosing the tip position, and the length of the inlet and withdrawal tubes of the ectopic catheter was observed and calculated by ultrasound and down-regulated to the appropriate position under ultrasound guidance. Results The display rate of catheter tip by bedside color Doppler ultrasound was 98.0%, and the accuracy rate of tip position was 90.2%. There was no significant difference compared with bedside X-ray (P = 0.375), and the tip position of the two examination methods was highly consistent (Kappa = 0.769, P<0.001). The sensitivity of diagnosing tip ectopy was 76.5% and the specificity was 97.1%, and the success rate of ectopic catheters in ultrasound-guided downsetting was 100%. Conclusion Bedside ultrasound accurately show the position of the catheter tip and guide the entry and withdrawal of ectopic catheter, with high sensitivity and specificity, which has high value of clinical promotion.
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.