Steel profile corrosion resistance in contact with monolithic foam concrete
1 Peter the Great St. Petersburg Polytechnic University, Politekhnicheskaya, 29, Saint-Petersburg, 195251, Russia
2 Sovbi, Ltd, Ispolkomskaya st., 4-6, letter A, room 4H, office 1, Saint-Petersburg, 191024, Russia
* Corresponding author: fishermanoff@mail.ru
The study evaluates corrosion resistance of steel profiles in contact with monolithic foam concrete with a thickness of 5 and 10 mm. There are two types of samples: structural steel ones and cold-formed galvanized steel ones. A visual examination of samples exposed to high temperature and relative humidity is carried out. The corrosion resistance of profiles made of structural steel and cold-formed galvanized steel in full contact with monolithic foam concrete provides. Metal passivation (formation of a protective film) occurs due to the high alkalinity of foam concrete. The pH values of concrete and concrete mixture, experimentally obtained, vary in the range of 12.18 ... 12.36 at all stages of the structural behavior. This indicates a favorable highly alkaline environment for profile steel.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.