Issue |
E3S Web Conf.
Volume 369, 2023
3rd International Conference on Environment Resources and Energy Engineering (ICEREE 2023)
|
|
---|---|---|
Article Number | 01012 | |
Number of page(s) | 5 | |
Section | Natural Resource Management and Environmental Control | |
DOI | https://doi.org/10.1051/e3sconf/202336901012 | |
Published online | 16 February 2023 |
Research on Thermal and Humidity Environment of Cultural Relics Exhibition Room
1
School of civil engineering, North China University of Technology, Beijing, China
2
School of civil engineering, North China University of Technology, Beijing, China
3
China Railway Construction Group Co., Ltd, Beijing, China
4
School of civil engineering, North China University of Technology, Beijing, China
a* E-mail: yuwenhong@ncut.edu.cn
b E-mail: 1515413987@qq.com
c E-mail: 824231822@qq.com
d E-mail: 876889427@qq.com
In order to meet the needs of humanistic education, museum buildings have developed vigorously in recent years. The protection and display of cultural relics is an effective way to continue historical information, which has important social and cultural significance. During the design and operation of the building air conditioning system, both the thermal and humidity environment of the cultural relics exhibition room should be responsible for the safety of the displayed cultural relics and the thermal comfort of visitors should be considered. In this paper, the indoor thermal and humidity environment of a cultural relic exhibition room in Beijing was measured, and the indoor air velocity distribution and temperature and humidity distribution were obtained. The results show that the thermal and humidity environment of the cultural relics exhibition room is better, but the indoor temperature of the exhibition room is lower, which still has great energy saving potential. It needs to be improved in the future engineering practice to achieve double optimization of comfort and energy saving effect. In order to achieve accurate control of the indoor thermal and humidity environment of the cultural relics exhibition room, we built a data collection for thermal environment parameters and air quality, which is used for monitoring and data collection of the cultural relics exhibition room.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.