Issue |
E3S Web of Conf.
Volume 389, 2023
Ural Environmental Science Forum “Sustainable Development of Industrial Region” (UESF-2023)
|
|
---|---|---|
Article Number | 01053 | |
Number of page(s) | 8 | |
Section | Materials Science Innovations, Green Chemistry and Emission Reduction | |
DOI | https://doi.org/10.1051/e3sconf/202338901053 | |
Published online | 31 May 2023 |
Robustness of the combined arch system with radial ties
1 National Research University Moscow State University of Civil Engineering (NRU MGSU), Yaroslavskoe shosse, 26, 129337, Moscow, Russia
2 Bauman Moscow State Technical University (National Research University), 2 Baumanskaya street, 5, building 1, 105005, Moscow, Russia
* Corresponding author: DolgushevaVV@yandex.ru
To ensure the safety of buildings and structures, it is necessary to analyze the structural integrity (robustness). The results of various studies show that arches with radial ties make it possible to create an architecturally expressive, cost-effective material consumption solution to the problem of girders bridging in public buildings, but the robustness of these systems is poorly studied. This article presents the results of the failure analysis of the coating elements in the form of combined steel arches with radial ties under various failure scenarios, the robustness of the n-th level in a static formulation is investigated, considering the geometrically nonlinear nature of the system operation, constructive measures are proposed to increase the robustness of a combined arch system with radial ties. The calculations were performed in the SCAD Office software 21.1.9.11. For the considered fragment of the scheme in both scenarios, the robustness index Irob > 98.5% corresponds to the local nature of the excess of the load-carrying ability, Irob ≤ 98.5% - to disproportional. As soon as the asymmetric prestressing of the arch by ties disappears, which occurs when the most loaded ties are turned off step by step, the system either satisfies the strength and stability tests, or the number of elements in which the load-carrying ability is exceeded significantly decreases. Increasing the structural integrity of the structure by introducing chordal ties into the scheme contributes to increasing the robustness of the considered arch system.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.