Concerning partial discharge detection in cable lines using high-frequency sensors
North-Caucasus Federal University, 355017 Stavropol, Russia
* Corresponding author: mdemin@ncfu.ru
Partial discharges result in cable line faults that can occur in defective insulation systems made of rubber, polyethylene, XLPE, and flexible PVC. Insulation defects may occur due to disruptions in their production process, cable installation, and operational conditions. Therefore, the diagnostic and monitoring of partial discharge occurrence in cable insulation help prevent emergencies in damaged cable line sections. Partial discharge registration is a non-destructive diagnostic method that helps assess the cable line condition and localize the detected defects. There are various methods of operational monitoring and partial discharge cause analysis based on operative partial discharge sensors. The assessment of cable line condition depends on the efficiency of signal detection and processing by the sensors used. This article reviews the problems of detecting and localizing partial discharges in cable lines and junction boxes using HFCT and UHF sensors. Having analyzed the capabilities of these sensors, we believe that the combined usage of HFCT and UHF sensors is the best method of detecting and localizing partial discharge within the entire cable system (lines and junction boxes).
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.