Issue |
E3S Web of Conf.
Volume 396, 2023
The 11th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings (IAQVEC2023)
|
|
---|---|---|
Article Number | 01031 | |
Number of page(s) | 6 | |
Section | Indoor Environmental Quality (IEQ), Human Health, Comfort and Productivity | |
DOI | https://doi.org/10.1051/e3sconf/202339601031 | |
Published online | 16 June 2023 |
Air quality investigation and research for various types of student-oriented indoor environments on a university campus
Department of Civil and Environmental Engineering, National University of Kaohsiung, No. 700, Kaohsiung University Rd., Kaohsiung, Taiwan
* Corresponding author: chichilin@nuk.edu.tw
This study investigated suspended particles (PM2.5 and PM10), formaldehyde, TVOC, ozone, carbon dioxide, and carbon monoxide in seven student-oriented indoor environments, which are inclusive of the library study room (A), computer classroom (B), teacher and student compound office (C), classroom-1 (D), classroom-2 (E), student cafeteria (F), and underground motorcycle parking lot (G) on a university campus. We monitored each indoor environment during the open hours for at least three weekdays. The averaged concentrations of CO2 in environments A, B, C, and D all exceeded the standard (1000 ppm) with values of 2,628±375, 1,908±613, 1,752±495, and 1,076±280 ppm. The corresponding minimum and maximum CO2 concentrations were 1,101 and 3,314, 836 and 3,272, 672 and 2,667, and 752 and 2,040 ppm, respectively. Sites A, B, C, D, F, and G are the environments where the concentrations of TVOC exceeded the standard (560 ppb) with the averaged values of 829±21, 920±192, 582±8, 607±15, 640±102 and 815±205 ppb, respectively. Both concentrations of PM2.5 and PM10 in site F exceeded the standards (i.e., 35 μg/m3 and 75 μg/m3) with averaged values of 39±13 μg/m3 and 103±51 μg/m3, respectively. Three target compounds, CO, O3, and HCHO, were below their respective standards.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.