Issue |
E3S Web of Conf.
Volume 396, 2023
The 11th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings (IAQVEC2023)
|
|
---|---|---|
Article Number | 01091 | |
Number of page(s) | 6 | |
Section | Indoor Environmental Quality (IEQ), Human Health, Comfort and Productivity | |
DOI | https://doi.org/10.1051/e3sconf/202339601091 | |
Published online | 16 June 2023 |
Effect of distance between occupants and insulation performance of window on contaminant distribution in a room with displacement ventilation
Division of Global Architecture, Graduate School of Engineering, Osaka University, Osaka, Japan,
* Shinnosuke ISHIKAWA : ishikawa_shinnosuke@arch.eng.osaka-u.ac.jp
In recent years, displacement ventilation system has received much attention in terms of infectious disease control, due to the epidemic of COVID-19 infections. Plume from occupants and the other heat sources is a very important factor for displacement ventilation because it determines the height of the contaminant stratification. Therefore, this paper aims at the effect of distance between occupants on distribution of temperature, contaminant concentration and plume from occupants in CFD analysis at first. The results suggest the specific distance where plume from occupant interfere with each other in the occupied zone. Our results also indicate that other conditions such as human body posture also affect the interference. In addition, since the aforementioned study don't take into account the influence of the temperature of window surface cooled by outside air, we vary the insulation performance of the window and check the concentration in the occupied area. The results are obtained that the amount of contaminants carried by the downward flow from the window to the lower part of the room depends on the insulation performance of the window, which affects the occupied zone.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.