The local heat transfer coefficient determination during boiling a subcooled liquid on a superheated surface by the gradient heatmetry
Peter the Great St. Petersburg Polytechnic University, Russia, 195251, St. Petersburg, Politekhnicheskaya, 29
The article presents a comparison of the experimental local heat transfer coefficient and the heat transfer coefficient obtained by well-known empirical formulas. To calculate the heat transfer coefficient for stable pool film boiling according to the formulas given in the classical literature, it is necessary to know exactly the thermophysical parameters of the liquid and vapor at a given pressure and temperature. This approach satisfactorily describes the heat transfer coefficient during the boiling of homogeneous liquids. When calculating the heat transfer coefficient during the boiling of a suspension of particles in a liquid such an approach is impossible, because the exact values of thermophysical parameters for such a system are unknown. A new approach is proposed for determining the local heat transfer coefficient during boiling using gradient heatmetery. The method based on the use of heterogeneous gradient heat flux sensors allows the direct measurement of the heat flux per unit area. And with a known temperature difference, using thermometry, according to Newton's law of cooling, it is possible to determine the local heat transfer coefficient without reference to the thermophysical parameters of the liquid and vapor.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.