Issue |
E3S Web Conf.
Volume 490, 2024
5th International Symposium on Architecture Research Frontiers and Ecological Environment (ARFEE 2023)
|
|
---|---|---|
Article Number | 03008 | |
Number of page(s) | 7 | |
Section | Ecological Environment Restoration and Pollution Control | |
DOI | https://doi.org/10.1051/e3sconf/202449003008 | |
Published online | 14 February 2024 |
Research on frost heave of channels in cold areas based on electroosmotic drainage
School of Civil Engineering, Lanzhou Jiaotong University, Lanzhou, Gansu, China
* Corresponding author: 1461778016@qq.com
In order to study the influence of electroosmosis treatment channel foundation soil on frost heave failure of concrete lining channel in cold areas under different voltages, the surface temperature of concrete lining was calculated according to the principles of atmospheric physics and thermal radiation. The finite element software was used to simulate the use of 20V, 40V and 60V voltage electroosmosis to treat the channel foundation soil, reduce the moisture content of the canal foundation soil, and numerically simulate the frost heave of the lining channel. The results show that after 20V, 40V and 60V voltage electroosmosis treatment, the moisture content of the base soil tends to be stable after 59h, 71h and 90h, respectively, and the moisture content can be reduced by 46.9%, 51.7% and 58.4% respectively compared with the non-electroosmosis treatment. The normal frost heave can be reduced by 37.4%, 42.3% and 49.0% respectively at 20V, 40V and 60V voltages. The normal frost heave force can be reduced by 14.3%, 22.4% and 30.6% respectively at 20V, 40V and 60V voltages. The tangential freezing force can be reduced by 14.3%, 25.1% and 33.9% respectively at 20V, 40V and 60V voltages. The results of this study can provide a reference for channel reduction of frost heave.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.