Issue |
E3S Web Conf.
Volume 523, 2024
53rd AiCARR International Conference “From NZEB to ZEB: The Buildings of the Next Decades for a Healthy and Sustainable Future”
|
|
---|---|---|
Article Number | 05001 | |
Number of page(s) | 16 | |
Section | Buildings in an Urban Scale | |
DOI | https://doi.org/10.1051/e3sconf/202452305001 | |
Published online | 07 May 2024 |
Shallow geothermal systems in dense urban areas: The issue of thermal interference and long-term sustainability
1 Politecnico di Milano, Department of Energy, Milano, Italy
2 Politecnico di Milano, Department of Civil and Environmental Engineering, Milano, Italy
* Corresponding author: adriana.angelotti@polimi.it
Shallow geothermal systems, namely Ground Source Heat Pumps (GSHP) and Ground Water Heat Pumps (GWHP), are expected to give an increasing contribution to the decarbonization of the buildings climatization sector. A fully sustainable use should guarantee fair access to the shallow geothermal sources for new systems, given the potential thermal interference among neighbouring ones in dense urban areas, and address environmental concerns related to thermal pollution of ground and groundwater. In this paper the state of the art concerning environmental concerns, regulation approaches and sustainability metrics is firstly reported. Then, focusing on closed-loop systems, a simulation case study is developed to study the long-term thermal footprint in the ground. The Energy Imbalance indicator, summarizing the annual energy balance in the ground, drives the thermal drift produced by the bore-field and is therefore proposed as the main sustainability indicator. For given ground conditions, a maximum Energy Imbalance is identified, which limits the thermal perturbation distance to the borehole spacing and minimizes thermal interference with other systems.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.