| Issue |
E3S Web Conf.
Volume 672, 2025
The 17th ROOMVENT Conference (ROOMVENT 2024)
|
|
|---|---|---|
| Article Number | 01044 | |
| Number of page(s) | 6 | |
| Section | Indoor Climate: IAQ | |
| DOI | https://doi.org/10.1051/e3sconf/202567201044 | |
| Published online | 05 December 2025 | |
An Interactive Biological Contaminant and CO2 Exposure Dose Calculation Tool
Univ Coimbra, ADAI, Department of Mechanical Engineering, Rua Luís Reis Santos, Pólo II, 3030-788 Coimbra, Portugal
An interactive computational tool based upon the differential equation modeling the time evolutions of the concentrations of both CO2 and a bio contaminant in an indoor uni-zone compartment was developed to support teaching and training activities during the COVID-19 pandemic. It uses the finite differences formulation, calculating the concentration change along equally spaced sampling time instants. The calculation tool has been developed in the LabView programming software, benefitting from its good graphical display tools. It was designed to allow the change of the governing parameters during the simulation of cases, allowing an immediate perception of the effect of the introduced changes. It takes into account the impact of the following variables: emission rate of bio contaminant source, half-life time of bio contaminant, efficiency of protective mask wearied by the emitter, efficiency of protective mask worn by the receiver, fresh air flow rate, volume of the room, number of occupants in the room and respective corpulence data and metabolic rate, flow rate of an indoor installed air cleaner device and individual one-pass purification efficiency. For a previously defined duration running test, the tool displays the time evolutions of the concentrations of CO2 and the bio contaminant and the time history of the dose inhaled by a receiver with and without a protective mask. The results presented in the paper refer to a parametric study where the air exchange rate, the use of protective masks, and an air cleaning device were changed in a typical classroom with 20 occupants.
Key words: Biocontaminant and CO2 Calculator / IAQ simulation / IAQ in School buildings
© The Authors, published by EDP Sciences, 2025
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.