| Issue |
E3S Web Conf.
Volume 689, 2026
14th International Symposium on Heating, Ventilation, and Air Conditioning (ISHVAC 2025)
|
|
|---|---|---|
| Article Number | 01001 | |
| Number of page(s) | 6 | |
| Section | Carbon Emission Assessment | |
| DOI | https://doi.org/10.1051/e3sconf/202668901001 | |
| Published online | 21 January 2026 | |
Evaluation of Urban CO2 Reduction Potential from Demand Response-Ready Residential Heat Pump Water Heaters
1 Waseda Research Institute for Science and Engineering, Waseda University, Tokyo, Japan
2 Advanced Collaborative Research Organization for Smart Society, Waseda University, Tokyo, Japan
3 Sustainable Energy & Environmental Society Open Innovation Research Organization, Waseda University, Tokyo, Japan
4 Taisei Advanced Center of Technology, TAISEI Corporation, Kanagawa, Japan
5 Department of Architecture, Waseda University, Tokyo, Japan
6 Department of Applied Mechanics and Aerospace Engineering, Waseda University, Tokyo, Japan
7 Department of Electrical Engineering and Bioscience, Waseda University, Tokyo, Japan
* Corresponding author: This email address is being protected from spambots. You need JavaScript enabled to view it.
Abstract
This study quantifies the CO₂ reduction potential of demand response (DR) operation of residential heat pump water heaters (HPWHs) in Utsunomiya City, Japan. An evaluation framework was developed by integrating spatiotemporal electricity demand and photovoltaic (PV) generation, both estimated from approximately 410,000 smart meters, along with dynamic grid carbon intensity. Scenario analyses assessed the combined impact of HPWH penetration, DR readiness, and PV adoption. Results show that enabling DR in existing HPWHs can reduce citywide CO₂ emissions from HPWHs by up to 34%, primarily by shifting operation to daytime with lower grid carbon intensity. When PV deployment was doubled or tripled, surplus PV utilization by HPWHs increased substantially, enhancing the CO₂ reduction effect of DR even at current penetration levels. However, the effectiveness of DR varies across the city, as surplus electricity remains scarce in dense areas with high demand. In the most ambitious scenario, where 80% of households adopt HPWHs and citywide PV generation triples, total CO₂ emissions from all residential water heating systems across the city could be reduced by up to 49%. Developing locally optimized strategies that integrate PV, HPWHs, and DR is essential for realizing effective urban decarbonization through DR operation of residential water heaters.
© The Authors, published by EDP Sciences, 2026
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.