Open Access
Issue
E3S Web Conf.
Volume 111, 2019
CLIMA 2019 Congress
Article Number 02075
Number of page(s) 7
Section Indoor Environment Quality and Others
DOI https://doi.org/10.1051/e3sconf/201911102075
Published online 13 August 2019
  1. D. Camuffo, P. Schenal, Indoor microclimate of the Scrovegni Chapel: mass and thermal exchanges between surfaces and idoor air (in Italian), Bollettino d’Arte, Edizione Speciale, Istituto Poligrafico e Zecca dello Stato, 107-209, 1982. [Google Scholar]
  2. C. Bonacina, P. Baggio, F. Cappelletti, P. Romagnoni, A.G. Stevan, The Scrovegni Chapel: The results of over 20 years of indoor climate monitoring, Energy and Buildings, 95, 144–152, 2015. [CrossRef] [Google Scholar]
  3. SYNCRO, The Scrovegni Chapel in Padova – Continuous monitoring of indoor thermal parameters (in Italian), Report for Padova Municipality, 1993. [Google Scholar]
  4. V. Fassina, Moisture problems inside the wall and facade protection (in Italian), Proceedings of the workshop “La Cappella degli Scrovegni - Indagini, restauri, interventi”- February 25th, Stampa Arti Grafiche Padovane, 37–41, 1998. [Google Scholar]
  5. M. Marabelli, Measurements and problems by pollutions and soluble salts (in Italian), Proceedings of the workshop “La Cappella degli Scrovegni - Indagini, restauri, interventi”– February 25th, Stampa Arti Grafiche Padovane, 48–53, 1998. [Google Scholar]
  6. C. Bonacina, P. Baggio, M. Mariotti, P. Romagnoni, Indoor microclimate management of the Scrovegni Chapel (in Italian), Proceedings of the workshop “La Cappella degli Scrovegni - Indagini, restauri, interventi”- February 25th, Stampa Arti Grafiche Padovane, 60–64,1998. [Google Scholar]
  7. X. Maldague, Theory and Practice of infrared technology for non-destructive testing, Wiley, 2001. [Google Scholar]
  8. A. Bortolin, G. Cadelano, G. Ferrarini, P. Bison F. Peron, X. Maldague, High resolution survey of buildings by lock-in IR thermography, SPIE vol. 8705, 1–7, 2013. [Google Scholar]
  9. E. Grinzato, C. Bressan, F. Peron, P. Romagnoni, A.G. Stevan, Indoor climatic conditions of ancient buildings by numerical simulation and thermographic measurements, SPIE vol. 4020, 314–323, 2000. [Google Scholar]
  10. E. Grinzato e M. Strada, F. Peron, Moisture monitoring of historical buildings by long period temperature measurements, SPIE vol. 3700, 471–482, 1999. [Google Scholar]
  11. E. Grinzato, N. Ludwig, G. Cadelano, M. Bertucci, M. Gargano, P. Bison, Infrared thermography for moisture detection: a laboratory study and in-situ test, Materials Evaluation, 69 (1), 97-104, 2011. [Google Scholar]
  12. E. Grinzato, C. Bressan, S. Marinetti, P.G. Bison, C. Bonacina. Monitoring of the Scrovegni Chapel by IR thermography: Giotto at infrared, Infrared Physics & Technology, Volume 43, Issues 3–5, 165-169, 2002. [CrossRef] [Google Scholar]
  13. P. Bison, F. Agrosì, A. Bortolin, G. Cadelano, G. Ferrarini, E. Grinzato, Water content classification in porous material by periodic forced ventilation, Proceedings of the 11th QIRT International Conference on Quantitative InfraRed Thermography, Naples (Italy), 2012. [Google Scholar]
  14. UNI 11085, Cultural heritage - Natural and artificial stone materials - Determination of water content: Weight method, Italian Bureau of Standard, 2003. [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.