Open Access
Issue
E3S Web Conf.
Volume 261, 2021
2021 7th International Conference on Energy Materials and Environment Engineering (ICEMEE 2021)
Article Number 01058
Number of page(s) 5
Section Energy Development and Energy Storage Technology Research and Development
DOI https://doi.org/10.1051/e3sconf/202126101058
Published online 21 May 2021
  1. THUBERC, 2018 Annual Report on China Building Energy Efficiency. 2018, Beijing. [Google Scholar]
  2. Wang, Q. and H.-N. Qiu, Situation and outlook of solar energy utilization in Tibet, China. Renewable and Sustainable Energy Reviews, 2009. 13 (8): p. 2181-2186. [Google Scholar]
  3. Yu, W., et al., A study of thermal comfort in residential buildings on the Tibetan Plateau, China. Building and Environment, 2017. 119 : p. 71-86. [Google Scholar]
  4. Ralegaonkar, R.V. and R. Gupta, Review of intelligent building construction: A passive solar architecture approach. Renewable and Sustainable Energy Reviews, 2010. 14 (8): p. 2238-2242. [Google Scholar]
  5. Olesen, B.W., Radiant floor heating in theory and practice. Ashrae Journal, 2002. 44 (7): p. 19-26. [Google Scholar]
  6. Zhao, K., X.-H. Liu, and Y. Jiang, Application of radiant floor cooling in a large open space building with high-intensity solar radiation. Energy and Buildings, 2013. 66 : p. 246-257. [Google Scholar]
  7. Zhao, K., X.-H. Liu, and Y. Jiang, Dynamic performance of water-based radiant floors during start-up and high-intensity solar radiation. Solar Energy, 2014. 101 : p. 232-244. [Google Scholar]
  8. Feng, J., S. Schiavon, and F. Bauman, New method for the design of radiant floor cooling systems with solar radiation. Energy and Buildings, 2016. 125 : p. 9-18. [CrossRef] [Google Scholar]
  9. Athienitis, A.K., Investigation of thermal performance of a passive solar building with floor radiant heating. Solar Energy, 1997. 61 (5): p. 337-345. [Google Scholar]
  10. Athienitis, A.K. and Y. Chen, The effect of solar radiation on dynamic thermal performance of floor heating systems. Solar Energy, 2000. 69 (3): p. 229-237. [Google Scholar]
  11. China, M.O.H.A.U.R.D.O.T.P.S.R.O., Design standard for energy efficiency of public buildings. 2015: Beijing. [Google Scholar]
  12. Zhou, J., et al., A dynamic model of hollow ventilated interior wall integrated with solar air collector. Applied Thermal Engineering, 2020. 175 . [Google Scholar]
  13. Zhao, K., X.-H. Liu, and Y. Jiang, On-site measured performance of a radiant floor cooling/heating system in Xi’an Xianyang International Airport. Solar Energy, 2014. 108 : p. 274-286. [Google Scholar]
  14. CEN, EN ISO 7730: Ergonomics of the Thermal Environment: Analytical Determination and Interpretation of the Thermal Comfort Using Calculation of the PMV And PPD Indices and Local Thermal Comfort Criteria. 2005, CEN. [Google Scholar]
  15. Qian, B., et al., Measurements of Energy Consumption and Environment Quality of HighSpeed Railway Stations in China. Energies, 2019. 13 (1). [Google Scholar]
  16. Lu, Y., Practical heating and air conditioning design manual. 1993, Beijing: China Architecture & Building Press. [Google Scholar]
  17. China, N.R.A.O.P.S.R.O., Code for Design of Railway Passenger Station. 2018: Beijing. [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.