Open Access
Issue
E3S Web Conf.
Volume 356, 2022
The 16th ROOMVENT Conference (ROOMVENT 2022)
Article Number 03017
Number of page(s) 5
Section Thermal Comfort and Natural Ventilation
DOI https://doi.org/10.1051/e3sconf/202235603017
Published online 31 August 2022
  1. T. Karimipanah and H. B. Awbi, “Theoretical and experimental investigation of impinging jet ventilation and comparison with wall displacement ventilation,” Build. Environ., vol. 37, no. 12, pp. 1329–1342, 2002, doi: 10.1016/S0360-1323(01)00117-2. [Google Scholar]
  2. P. Rohdin and B. Moshfegh, “Numerical predictions of indoor climate in large industrial premises. A comparison between different k-ε models supported by field measurements,” Build. Environ., vol. 42, no. 11, pp. 3872–3882, 2007, doi: 10.1016/j.buildenv.2006.11.005. [Google Scholar]
  3. H. J. Chen, B. Moshfegh, and M. Cehlin, “Numerical investigation of the flow behavior of an isothermal impinging jet in a room,” Build. Environ., vol. 49, no. 1, pp. 154–166, 2012, doi: 10.1016/j.buildenv.2011.09.027. [Google Scholar]
  4. X. Ye, H. Zhu, Y. Kang, and K. Zhong, “Heating energy consumption of impinging jet ventilation and mixing ventilation in large-height spaces: A comparison study,” Energy Build., 130, pp. 697–708, 2016, doi: 10.1016/j.enbuild.2016.08.055. [Google Scholar]
  5. X. Ye, Y. Kang, B. Zuo, and K. Zhong, “Study of factors affecting warm air spreading distance in impinging jet ventilation rooms using multiple regression analysis,” Build. Environ., 120, 1–12, 2017, doi: 10.1016/j.buildenv.2017.03.044. [Google Scholar]
  6. E. A. Arens et al., ASHRAE-55:Thermal Environmental Conditions for Human Occupancy. 2017. [Google Scholar]
  7. ISO 7730, “ISO 7730: Ergonomics of the thermal environment Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria,” Management, vol. 3, pp. 605–615, 2005, [Online]. Available: http://linkinghub.elsevier.com/retrieve/pii/S026 7726105000503. [Google Scholar]
  8. P. O. F. B.W. Olesen, M. Scholer, Discomfort Caused By Vertical Air Temperature differences. Denmark: Danish Building Research Institute, 1979. [Google Scholar]
  9. K. W. D. Cheong, W. J. Yu, K. W. Tham, S. C. Sekhar, and R. Kosonen, “A study of perceived air quality and sick building syndrome in a field environment chamber served by displacement ventilation system in the tropics,” Build. Environ., vol. 41, no. 11, pp. 1530–1539, 2006, doi: 10.1016/j.buildenv.2005.06.003. [Google Scholar]
  10. N. HASHIGUCHI, T. KUMAMOTO, A. CHISHAKI, and Y. TOCHIHARA, “Effects of Vertical Air Temperature Gradients on Physiological and Psychological Responses in the Elderly,” Journal of the Human-Environment System, 14, no. 1. pp. 9–17, 2011, doi: 10.1618/jhes.14.9. [CrossRef] [Google Scholar]
  11. S. Liu et al., “Predicted percentage dissatisfied with vertical temperature gradient,” Energy Build., vol. 220, 2020, doi: 10.1016/j.enbuild.2020.110085. [Google Scholar]
  12. W. J. Yu, K. W. D. Cheong, K. W. Tham, S. C. Sekhar, and R. Kosonen, “Thermal effect of temperature gradient in a field environment chamber served by displacement ventilation system in the tropics,” Build. Environ., vol. 42, no. 1, pp. 516–524, 2007, doi: 10.1016/j.buildenv.2005.09.003. [Google Scholar]
  13. S. S. Shapiro and R. S. Francia, “An approximate analysis of variance test for normality,” J. Am. Stat. Assoc., vol. 67, no. 337, pp. 215–216, 1972, doi: 10.1080/01621459.1972.10481232. [Google Scholar]
  14. M. Hollander, D. A. Wolfe, and E. Chicken, “Nonparametric statistical methods,” Nonparametric Stat. Methods, pp. 1–819, 2015, doi: 10.1002/9781119196037. [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.