Open Access
Issue |
E3S Web of Conf.
Volume 559, 2024
2024 International Conference on Sustainable Technologies in Civil and Environmental Engineering (ICSTCE 2024)
|
|
---|---|---|
Article Number | 04018 | |
Number of page(s) | 5 | |
Section | Structural Engineering & Concrete Technology | |
DOI | https://doi.org/10.1051/e3sconf/202455904018 | |
Published online | 08 August 2024 |
- KMK 2.03.11-96. Zaщita stroitelnыx konstruksiy ot korrozii. Goskomarxitektstroy R.Uz. Tashkent, 1996 g. – 142 s. [Google Scholar]
- Rashidov T.R., Sirojiddinov Z.S. Problemы obespecheniya soxrannosti pamyatnikov arxitekturы // Problemы mexaniki. 2002. №5. S. 7-13. [Google Scholar]
- Durdiyeva G.S. Zargarov T.K. Janubiy Orolbo’yi me’moriy ѐdgorliklarning qurilmalariga yer osti suvining salbiy ta’siri // “Xorazm vohasi sharoitida yersuv resurslaridan samarali foydalanish va tuproq meliorasiyasi muammolari” anjuman materiallari. Xiva, 2011, B. 50-52. [Google Scholar]
- Alfano F. R. A., Palella B. I., Riccio G. Moisture in historical buildings from causes to the application of specific diagnostic methodologies //Journal of Cultural Heritage. – 2023. – Т. 61. – С. 150-159. https://doi.org/10.1016/j.culher.2023.04.001 [Google Scholar]
- E. Franzoni, Rising damp removal from historical masonries: a still open challenge, Constr. Build. Mater. 54 (2014) 123–136, doi:10.1016/j.conbuildmat.2013.12.054. [CrossRef] [Google Scholar]
- P. Št’astný, J. Gašparík, O. Makýš, B. Chamulová, P.S. Szalayová, Application of anti-moisture technologies in historical constructions from the perspective of sustainability, Appl. Sci. 11 (2021) 9659, doi:10.3390/app11209659. [CrossRef] [Google Scholar]
- E. Franzoni, State-of-the-art on methods for reducing rising damp in masonry, J. Cult. Herit. 31 (2018) S3–S9, doi:10.1016/j.culher.2018.04.001 . [CrossRef] [Google Scholar]
- D.R. Salmon, R.G. Williams, R.P. Tye, Thermal conductivity and moisture measurements on masonry materials, ASTM Spec. Techn. Publ. 1426 (2002) 58–78. [Google Scholar]
- A.G.Perexojensev. Modelirovaniye temperaturnovlajnostnыx prosessov v poristыx stroitelnыx materialax. Ch.1. Model poristogo materiala i vыbor vlajnostnыx xarakteristik dlya issledovaniya porыstoy strukturы materialov. Stroitelnыye materialы. Nauchnotexnicheskiy i proizvodstvennыy jurnal. Dekabr, 2012. S.45-47. [Google Scholar]
- C. Riminesi, A. Sansonetti, A. Scala, Assessment of the effectiveness of a dehumidification system by emission of electromagnetic fields: proposal of a protocol, J. Cult. Herit. 31 (2018) S46–S51, doi:10.1016/j.culher.2018.04.002. [CrossRef] [Google Scholar]
- D. Camuffo, How much temperature will increase the efficiency of electroosmosis? J. Cult. Herit. 36 (2019) 264–267, doi:10.1016/j.culher.2018.09.002. [CrossRef] [Google Scholar]
- Nicodemo G., Peduto D., Ferlisi S. Building damage assessment and settlement monitoring in subsidenceaffected urban areas: case study in the Netherlands //Proceedings of the International Association of Hydrological Sciences. – 2020. – Т. 382. – С. 651-656. doi:10.5194/piahs-382-651-2020. [Google Scholar]
- H. Janssen, J. Carmeliet, H. Hens, The influence of soil moisture transfer on building heat loss via the ground, Build. Environ. 39 (2004) 825–836, doi:10.1016/j.buildenv.2004.01.004. [CrossRef] [Google Scholar]
- M. Abuku, B. Blocken, S. Roles, Moisture response of building façades to wind-driven rain: field measurements compared with numerical simulations, J. Wind Eng. Ind. Aerodyn. 97 (2009) 197–207, doi:10.1016/j.jweia.2009.06.006. [CrossRef] [Google Scholar]
- Methods of Measuring Moisture in Building Materials and Structures. Stateof-the-Art Report of the RILEM Technical Committee 248-MMB Editors: Nilsson, Lars-Olof (Ed.) Springer International Publishing. DOI 10.1007/978-3-319-74231-1 [Google Scholar]
- G. Massari, I. Massari, Damp buildings, Old and New, ICCROM, Rome, 1993. [Google Scholar]
- S.C. Chien, C.Y. Ou, Y.C. Lee, A novel electroosmotic chemical treatment technique for soil improvement, Appl. Clay Sci. 50 (4) (2010) 481–492, doi:10.1016/j.clay.2010.09.014. [CrossRef] [Google Scholar]
- Y. Vanhellemont, J. Bolhuisb, M. de Bouwa, S. Dubois S, B. Lubelli, L. Miedema, R. van Hees, Are electrokinetic methods suitable for the treatment of rising damp? J. Cult. Herit. 31 (2018) S23–S29, doi:10.1016/j.culher.2018.04.010. [CrossRef] [Google Scholar]
- P. Š ťastný, J. Gašparík, O. Makýš, Analysis of moisture and salinity of historical constructions before and after the application of remediations, J. Build. Eng. 41 (2021) 102785, doi:10.1016/j.jobe.2021.102785. [CrossRef] [Google Scholar]
- R.P.J. van Hees, B. Lubelli B, A. Hacquebord, New test methods to verify the performance of chemical injections to deal with rising damp, J. Cult. Herit. 31 (2018) S52–S59, doi:10.1016/j.culher.2018.03.024. [CrossRef] [Google Scholar]
- E. Franzoni, E. Rirsch, Y. Paselli, Which methods are suitable to assess the effectiveness of chemical injection treatments in the laboratory? J. Build. Eng. 29 (2020) 101131, doi:10.1016/j.jobe.2019.101131. [CrossRef] [Google Scholar]
- Inoyatov D.T. Energiya samarador binolarning sokol devorlari orqali o’tadigan namlikdan saqlash usullarini takomillashtirish: diss. PhD: 05.09.01 / Inoyatov Dilovar Tolibovich. – Toshkent, 2022 – 140 b. [Google Scholar]
- Tulakov, E. S., D. T. Inoyatov, and A. S. Kurbonov. “Waterproofing and calculation of the thickness of the insulation of the basement wall of a low-rise energy-efficient house in accordance with domestic and foreign standards and norms.” International Journal of Scientific and Technology Research 8.11 (2019): 3311-3314. [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.