Open Access
| Issue |
E3S Web Conf.
Volume 672, 2025
The 17th ROOMVENT Conference (ROOMVENT 2024)
|
|
|---|---|---|
| Article Number | 01026 | |
| Number of page(s) | 8 | |
| Section | Indoor Climate: Health Aspects | |
| DOI | https://doi.org/10.1051/e3sconf/202567201026 | |
| Published online | 05 December 2025 | |
- J. Gu, B. Han, J. Wang. COVID-19: Gastrointestinal manifestations and potential fecal-oral transmission. Gastroenterology 158, 1518-1519 (2020) [Google Scholar]
- M. Elsamadony, M. Fujii, T. Miura, T. Watanabe. Possible transmission of viruses from contaminated human feces and sewage: Implications for SARS-CoV-2. Sci. Total Environ 755, 142575 (2021) [Google Scholar]
- S. Vardoulakis, DAE. Oyarce, E. Donner. Transmission of COVID-19 and other infectious diseases in public washrooms: A systematic review. Sci. Total Environ 803, 149932 (2022) [CrossRef] [Google Scholar]
- X. Hu, Y. Xing, W. Ni, F. Zhang, S. Lu, Z. Wang, R. Gao, F. Jiang. Environmental contamination by SARS-CoV-2 of an imported case during incubation period. Sci. Total Environ 742, 140620 (2020) [Google Scholar]
- K.S. Cheung, I.F.N. Hung, P.P.Y. Chan, K.C. Lung, E. Tso, R. Liu, Y.Y. Ng, M.Y. Chu, T.W.H. Chung, A.R. Tam, C.C.Y. Yip, K.H. Leung, A.Y.F. Fung, R.R. Zhang, Y. Yang, H. Cheng, A.J.X Zhang, K.K.W. To, K.H. Chan, K.Y. Yuen, W.K. Leung. Gastrointestinal manifestations of SARS- CoV-2 infection and virus load in fecal samples from a Hong Kong cohort: systematic review and meta-analysis. Gastroenterology 159, 81-95 (2020). [Google Scholar]
- M. Gormley, T. J. Aspray, D. A. Kelly, C. Rodriguez-Gil. Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig. PLoS One 12, e0171556 (2017) [Google Scholar]
- B.H. Ali, M.S. Shahin, M.S. Shahin, M.M.M. Sangani, M. Faghihinezhad, M. Baghdadi, T.T. Lim. Wastewater aerosols produced during flushing toilets, WWTPs, and irrigation with reclaimed municipal wastewater as indirect exposure to SARS-CoV-2. J. Environ. Chem. Eng 9, 106201 (2021) [Google Scholar]
- M. Gormley, T. J. Aspray, D.A. Kelly. Aerosol and bioaerosol particle size and dynamics from defective sanitary plumbing systems. Indoor Air 31, 1427-1440 (2021) [CrossRef] [PubMed] [Google Scholar]
- Q. Wang, Y. Guo, D.C. Lung, P.T. Chan, C.H. Dung, W. Jia, T. Miao, J. Huang, W. Chen, Z. Wang, K.M. Leung, Z. Lin, D. Wong, H. Tse, S.C.Y. Wong, G.K.Y. Choi, J.Y.W. Lam, K.K.W. To, V.C.C. Cheng, K.Y. Yuen. Aerosol transmission of SARS-CoV-2 due to the chimney effect in two high-rise housing drainage stacks. J. Hazard. Mater 421, 126799 (2022) [Google Scholar]
- M. Gormley, K.E. Templeton, D.A. Kelly, A. Hardie. Environmental conditions and the prevalence of norovirus in hospital building drainage system wastewater and airflows. Build Serv. Eng. Res. Technol 35, 244-253 (2014) [Google Scholar]
- P. Zhao. Analysis of COVID-19 clusters involving vertical transmission in residential buildings in Hong Kong. Build. Simul 16, 701-711 (2022) [Google Scholar]
- M. Kang, J. Wei, J. Yuan, J. Guo, Y. Zhang, J. Hang, Y. Qu, H. Qian, Y. Zhuang, X. Chen, X. Peng, T. Shi, J. Wang, J. Wu, T. Song, J. He, Y. Li, N. Zhong. Probable evidence of fecal aerosol transmission of SARS-CoV-2 in a high-rise building. Ann. Intern. Med 173, 974-980 (2020) [Google Scholar]
- X. Li, B. Sun, K. Lyu, J. Chen, Y. Zhang, Y. Sun, C. Li, T. Sui, X. Wang, Y. Hu, Q. Wang, D. Xu. Research on the relationship between architectural features in northeast China and vertical aerosol transmission of COVID-19. Front. Public Health 10, 1052610 (2023) [Google Scholar]
- T. Han, H. Park, Y. Jeong, J. Lee, E. Shon, M.S. Park, M. Sung. COVID-19 cluster linked to aerosol transmission of SARS-CoV-2 via floor drains. J. Infect. Dis 225, 1554-1560 (2022) [Google Scholar]
- G. Lin, S. Zhang, Y. Zhong, L. Zhang, S. Ai, K. Li, W. Su, L. Cao, Y. Zhao, F. Tian, J. Li, Y. Wu, C. Guo, R. Peng, X. Wu, P. Gan, W. Zhu, H. Lin, Z. Zhang. Community evidence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV- 2) transmission through air. Atmospheric Environ 246, 118083 (2021) [Google Scholar]
- V. M.C. Fernandes, O.M. Gonçalves. Limits for use of vent elements in building drainage systems considering the risks of infection spread by means of water-seal behaviour and integrity: the case of Brazilian systems. Build Serv. Eng. Res. Technol 27, 103-117 (2006). [Google Scholar]
- X. Jiang, C. Zhao, Y. Chen, X. Gao, Q. Zhang, Z. Chen, C. Li, X. Zhao, Z. Liu, W. Huang, W. Xie, Y. Yue. Probable evidence of aerosol transmission of SARS-COV-2 in a COVID-19 outbreak of a high-rise building. Environ. Health Insights 17, 1-8 (2023) [Google Scholar]
- Q. Wang, L. Zhang, J. Niu, G.K.Y. Choi, J.C.H. Fung, A.K.H. Lau, P. Louie, K.K.M. Leung, J. Huang, P. Cheng, P. Zhao, W. Chen, S. Zhang, L. Fu, P.W. Chan, A.H. Wong, H. Tse, S.C.Y. Wong, R.W.M. Lai, D.S.C. Hui, K.Y. Yuen, D.C. Lung, Y. Li. Spread of SARS-CoV-2 aerosols via two connected drainage stacks in a high-rise housing outbreak of COVID-19. J. Hazard. Mater 430, 128475 (2022) [Google Scholar]
- C.P. Gerba, C. Wallis, J.L. Melnick. Microbiological hazards of household toilets: droplet production and the fate of residual organisms. Appl. Environ. Microbiol 30, 229-237 (1975) [Google Scholar]
- Z. Ding, H. Qian, B. Xu, Y. Huang, T. Miao, H. Yen, S. Xiao, L. Cui, X. Wu, W. Shao, Y. Song, L. Shao, L. Zhou, Y. Xu, B. Zhu, Y. Li. Toilets dominate environmental detection of severe acute respiratory syndrome coronavirus 2 in a hospital. Sci. Total Environ 753, 141710 (2021) [Google Scholar]
- Y. Li, J. Wang, X. Chen. Can a toilet promote virus transmission? From a fluid dynamics perspective. Phys. Fluids 32, 065107 (2020) [Google Scholar]
- M. Lou, S. Liu, C. Gu, H. Hu, Z. Tang, Y. Zhang, C. Xu, F. Li. The bioaerosols emitted from toilet and wastewater treatment plant: a literature review. Environ. Sci. Pollut. Res. 28, 2509-2521 (2020) [Google Scholar]
- V.C.C. Cheng, S.C. Wong, A.K.W. Au, C. Zhang, J.H.K. Chen, S.Y.C. So, X. Lin, Q. Wang, K.K. Lu, D.C. Lung, V.W.M. Chuang, E. Schuldenfrei, G.K.H. Siu, K.K.W. To, Y. Li, K.Y. Yuen. Explosive outbreak of SARS-CoV-2 Omicron variant is associated with vertical transmission in high-rise residential buildings in Hong Kong. Build. Environ 221, 109323 (2022) [Google Scholar]
- L.T. Wong, K.W. Mui, P.S. Hui. Air pressure variations at drainage stacks of high-rise residential buildings. Facilities 26, 463-469 (2008) [Google Scholar]
- L. Jack. Drainage design: factors contributing to Sars transmission. Proc. Inst. Civil Eng.-Munic. Eng 159, 43-48 (2006) [Google Scholar]
- L.B. Jack, C. Cheng, W. Lu. Numerical simulation of pressure and airflow response of building drainage ventilation systems. Build Serv. Eng. Res. Technol 27, 141-152 (2006) [Google Scholar]
- M. Gormley, D.A. Kelly. Pressure transient suppression in drainage systems of tall buildings. Build. Res. Informat 47, 421-436 (2019) [Google Scholar]
- J.A. Swaffield, L.B. Jack. Simulation and analysis of airborne cross-contamination routes due to the operation of building drainage and vent systems. Build. Res. Informat 32, 451-467 (2004) [Google Scholar]
- K. Fujimura, K. Sakaue. Analysis of pneumatic pressure vibration affected by connecting WCs and discharge load types. Water 9, 382 (2017) [Google Scholar]
- M. Gormley, D.A. Kelly, T.J. Aspray. Bio-aerosol cross-transmission via the building drainage system. in Proceedings of the International Society of Indoor Air Quality and Climate 7-12 July 2014, UK (2014) [Google Scholar]
- H.C.K. Hung, D.W.T. Chan, L.K.C Law, E.H.W. Chan, E.S.W. Wong. Industrial experience and research into the causes of SARS virus transmission in a high-rise residential housing estate in Hong Kong. Build Serv. Eng. Res. Technol 27, 91-102 (2006) [Google Scholar]
- C. Cheng, W. Lu, M. Shen. An empirical approach: Prediction method of air pressure distribution on building vertical drainage stack. Chin. Inst. Eng 28, 205-217 (2005) [Google Scholar]
- J.A. Swaffield, D.P. Campbell. The simulation of air pressure propagation in building drainage and vent systems. Build. Environ 30, 115-127 (1995) [Google Scholar]
- Z. Zhang, X. Li, Q. Wang, X. Zhao, J. Xu, Q. Jiang, S. Jiang, J. Lyu, S. Liu, L. Ye, J. Yuan, W. Feng, J. Xie, Q. Chen, H. Zou, D. Xu. Simulation studies provide evidence of aerosol transmission of SARS-CoV-2 in a multi-story building via air Supply, exhaust and sanitary pipelines. Int. J. Environ. Res. Public Health 19, 1532 (2022). [Google Scholar]
- K. Lyu, Q. Wang, X. Li, Z. Zhang, X. Zhao, Y. Li, Z. Tang, L. Li, F. Deng, X. Zhang, K. Xu, R. Zhao, D. Xu. Neglected aspects of SARS-CoV-2 aerosol transmission in bathrooms of multistory and high-rise building. CCDC Weekly 5, 1-4 (2023) [Google Scholar]
- K. Lyu, S. Feng, X. Li, Q. Wang, X. Zhao, S. Yu, P. Zheng, J. Ji, G. Chen, J. Liang, T. Lan, J. Feng, S. Jiang, J. Lu, T. Xia, C. Peng, T. Feng, D. Xu. SARS-CoV-2 aerosol transmission through vertical sanitary drains in high-rise buildings. CCDC Weekly 4, 489-493 (2022) [Google Scholar]
- Z. Ai, C.M. Mak, N. Gao, J. Niu. Tracer gas is a suitable surrogate of exhaled droplet nuclei for studying airborne transmission in the built environment. Build. Simul 13, 489-496 (2020) [Google Scholar]
- X. Cao, G. Hao, Y. Li, M. Wang, J. Wang. On male urination and related environmental disease transmission in restrooms: From the perspectives of fluid dynamics. Sust. Cities Soc 80, 103753 (2022) [Google Scholar]
- D.L. Johnson, K.R. Mead, R.A. Lynch, D.V.L. Hirst. Lifting the lid on toilet plume aerosol: A literature review with suggestions for future research. Am. J. Infect. Control 41, 254-258 (2013) [Google Scholar]
- D. Luo, J. Huang, X. Zheng, F. Liu, Y. Guo, Y. Wang, H. Qian. Spread of flushing-generated fecal aerosols in a squat toilet cubicle: Implication for infection risk. Sci. Total Environ 859, 160212 (2023) [Google Scholar]
- I.T.S. Yu, Y. Li, T.W. Wong, A.T. Chan, J.H.W. Lee, D.Y.C. Leung, T. Ho. Evidence of airborne Transmission of the severe acute respiratory syndrome virus. N Engl J Med 350, 1731-1739 (2004) [Google Scholar]
- J. Wang, T. Zhang, S. Wang, F. Battaglia. Gaseous pollutant transmission through windows between vertical floors in a multistory building with natural ventilation. Energy Build 153, 325-340 (2017) [Google Scholar]
- Y. Zhang, Y. Wang, F. Wang, X. Xu, X. Wu. Numerical investigation on the transmission and dispersion of aerosols in a 7-stories building drainage system. Build. Environ 201, 108009 (2021) [Google Scholar]
- C. Cheng, Y. Lin. CFD numerical simulation in building drainage stacks as an infection pathway of COVID-19. Int. J. Environ. Res. Public Health 19, 7475 (2022) [Google Scholar]
- J. Mao, W. Yang, N. Gao. The transport of gaseous pollutants due to stack and wind effect in high-rise residential buildings. Build. Environ 94, 543-557 (2015) [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.

