Open Access
| Issue |
E3S Web Conf.
Volume 672, 2025
The 17th ROOMVENT Conference (ROOMVENT 2024)
|
|
|---|---|---|
| Article Number | 03009 | |
| Number of page(s) | 8 | |
| Section | Ventilation & Energy Efficiency: Wind and Natural Ventilation | |
| DOI | https://doi.org/10.1051/e3sconf/202567203009 | |
| Published online | 05 December 2025 | |
- Rune Vinther Andersen,*, Jørn Toftum, Klaus Kaae Andersen, Bjarne W. Olesen, Energy and Buildings 41 (2009) 11–16 [Google Scholar]
- Europenan Commission, 2009, EU energy and transport in figures, ISSN 1725-1095, ISBN 978- 92-79-10728-3 [Google Scholar]
- Xilei Dai, Junjie Liu ⇑, Xin Zhang, A review of studies applying machine learning models to predict occupancy and window-opening behaviours in smart buildings, Energy & Buildings 223 (2020) 110159 [Google Scholar]
- Awbi, H. B. (1991), Ventilation of Buildings, Chapman & Hall, London, United Kingdom [Google Scholar]
- Birgitta Nordquist, (2002), Ventilation and Window Opening in Schools, Department of Building Services, Lund University, Lund, Sweden, Doctoral thesis TABK—02/1024 [Google Scholar]
- Per Heiselberg, Kjeld Svidt, Peter V. Nielsen, Characteristics of airflow from open windows, Building and Environment, Volume 36, Issue 7, 2001, Pages 859-869, DOI: 10.1016/S0360-1323(01)00012-9 [Google Scholar]
- Małgorzata Król, Aleksander Król, Piotr Koper, Jakub Bielawski, Grzegorz Krajewski, Wojciech Węgrzyński, Wind driven natural flow through the different types of openings on the façade - An experimental investigation, Journal of Building Engineering, Volume 71, 2023, 106491, DOI: 10.1016/j.jobe.2023.106491 [Google Scholar]
- Shinsuke Kato, Shuzo Murakami, Akashi Mochida, Shin-ichi Akabayashi, Yoshihide Tominaga, Velocity-pressure field of cross ventilation with open windows analyzed by wind tunnel and numerical simulation, Journal of Wind Engineering and Industrial Aerodynamics, Volume 44, Issues 1–3, 1992, Pages 2575-2586, DOI: 10.1016/0167-6105(92)90049-G [Google Scholar]
- Yoshihide Tominaga, Bert Blocken, Wind tunnel experiments on cross-ventilation flow of a generic building with contaminant dispersion in unsheltered and sheltered conditions, Building and Environment, Volume 92, 2015, Pages 452-461, DOI: 10.1016/j.buildenv.2015.05.026. [Google Scholar]
- Jörn von Grabe, Petr Svoboda, Armin Bäumler, Window ventilation efficiency in the case of buoyancy ventilation, Energy and Buildings, Volume 72, 2014, Pages 203-211, DOI: 10.1016/j.enbuild.2013.10.006. [Google Scholar]
- P. Karava, T. Stathopoulos & A.K. Athienitis (2004) Wind Driven Flow through Openings – A Review of Discharge Coefficients, International Journal of Ventilation, 3:3, 255-266, DOI: 10.1080/14733315.2004.11683920 [Google Scholar]
- Caiqing Yang, Hui Shi, Xudong Yang & Bin Zhao (2010) Research on Flow Resistance Characteristics with Different Window/Door Opening Angles, HVAC&R Research, 16:6, 813-824, DOI: 10.1080/10789669.2010.10390936 [Google Scholar]
- Erin L. Hult, Gianluca Iaccarino, Martin Fischer, Using CFD Simulations to Improve the Modeling of Window Discharge Coefficients, Fifth National Conference of IBPSA-USA Madison, Wisconsin August 1-3, 2012 [Google Scholar]
- Per Heiselberg, Erik Bjørn & Peter V. Nielsen (2002) Impact of Open Windows on Room Air Flow and Thermal Comfort, International Journal of Ventilation, 1:2, 91-100, DOI: 10.1080/14733315.2002.11683625 [Google Scholar]
- Birgitta Nordquist, (1998), Vädring I skolor – ett 077komplement till normal ventilation? Department of Building Services, Lund University, Lund, Sweden, Report TABK— 98/1014 [Google Scholar]
- Max H Sherman, David J. Wilson, Darwin Kiel, Variability in Residential Air Leakage. Measured Air Leakage Performance of Buildings, (Trechsel/Lagus Ed.) STP:904 (1986) 348-364. [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.