Open Access
| Issue |
E3S Web Conf.
Volume 680, 2025
The 4th International Conference on Energy and Green Computing (ICEGC’2025)
|
|
|---|---|---|
| Article Number | 00017 | |
| Number of page(s) | 13 | |
| DOI | https://doi.org/10.1051/e3sconf/202568000017 | |
| Published online | 19 December 2025 | |
- B. Singh, A. Chandra, and K. Al Haddad, Power Quality: Problems and Mitigation Techniques (Wiley, United Kingdom, 2015) [Google Scholar]
- É. Félice, P. Révilla, Qualité des réseaux électriques et efficacité énergétique (Dunod, Paris, 2012) [Google Scholar]
- M. Marquardt, Modular multilevel converter: a new concept for medium voltage drives. In: PCIM Europe Conf. (2003) [Google Scholar]
- J. Rodriguez, J. S. Lai, F. Z. Peng, Multilevel inverters: A survey of topologies, controls, and applications. IEEE Trans. Ind. Electron. 49(4), 724-738 (2002). https://doi.org/10. 1109/TIE.2002.801052 [CrossRef] [Google Scholar]
- A. K. Verma, S. Bhattacharya, and F. Zare, Adaptive harmonic current extraction using hybrid SRF-pq theory and neural learning. IEEE Trans. Ind. Electron. 70(4), 3578–3588 (2023). https://doi.org/10.1109/TIE.2023.3240185 [Google Scholar]
- J. Chen, M. Li, and P. Wang, Fuzzy-logic-enhanced dq-based control for grid-tied converters under unbalanced conditions. Electr. Power Syst. Res. 212, 108609 (2022). https://doi.org/10.1016/j.epsr.2022.108609 [Google Scholar]
- H. Akagi, Y. Kanazawa, A. Nabae, Instantaneous power theory and applications to compensation. IEEE Trans. Power Electron. PE-1(3), 131-138 (1984). https://doi.org/10. 1109/TPEL.1984.4788252 [Google Scholar]
- H. Akagi, Y. Kanazawa, A. Nabae, Instantaneous Power Theory and Applications to Power Conditioning (IEEE Press/Wiley, Hoboken, NJ, 2017) [Google Scholar]
- A. H. Nohra, Commande de filtres actifs parallèles sur un réseau fortement perturbé, PhD Thesis, INPT Toulouse & Université Saint-Joseph (2017). https://theses. hal.science/tel-04217007v1 [Google Scholar]
- V. Soares, P. Verdelho, G. D. Marques, An instantaneous active and reactive current component method for active filters. IEEE Trans. Power Electron. 15(4), 660–669 (2000). https://doi.org/10.1109/63.849049 [Google Scholar]
- S. Bhattacharya, D. M. Divan, B. Banerjee, Synchronous Reference Frame Harmonic Isolator Using Series Active Filter. In: Proc. 4th Eur. Power Electron. Conf. (EPE), Florence (1991), pp. 030-035 [Google Scholar]
- S. Golestan, J. M. Guerrero, Conventional synchronous reference frame phase-locked loop is an adaptive complex filter. IEEE Trans. Ind. Electron. 62(3), 1679-1682 (2015). https://doi.org/10.1109/TIE.2014.2327591 [Google Scholar]
- L. Tong, X. Zou, S. Feng, et al., An SRF-PLL-based sensorless vector control using the predictive deadbeat algorithm for the direct-driven permanent magnet synchronous generator. IEEE Trans. Power Electron. 29(6), 2837-2849 (2014). https://doi.org/10. 1109/TPEL.2013.2278882 [Google Scholar]
- M. Niaré, F. Danioko, M. Dansoko, M. L. Doumbia, Amélioration de la qualité d’un réseau électrique par correction de déséquilibre de phases par la technique du filtrage actif. Centre de Calcul, Université de Bamako et Université du Québec à Trois-Rivières (2020) [Google Scholar]
- B. A. Angélico, L. B. G. Campanhol, S. A. Oliveira da Silva, PI/PID tuning of a single-phase shunt APF using Bode diagram. IET Power Electron. 7(10), 2647-2659 (2014). https://doi.org/10.1049/iet-pel.2013.0574 [Google Scholar]
- M. H. J. Bollen, Understanding Power Quality Problems: Voltage Sags and Interruptions (IEEE Press, New York, 2000) [Google Scholar]
- IEEE Std 519-2014, IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems (IEEE, 2014) [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.