Open Access
| Issue |
E3S Web Conf.
Volume 689, 2026
14th International Symposium on Heating, Ventilation, and Air Conditioning (ISHVAC 2025)
|
|
|---|---|---|
| Article Number | 02001 | |
| Number of page(s) | 6 | |
| Section | Energy Efficient HVAC System and Technologies | |
| DOI | https://doi.org/10.1051/e3sconf/202668902001 | |
| Published online | 21 January 2026 | |
- I. Dincer, Energy and Environmental Impacts: Present and Future Perspectives. Energy Sources. 20, 427–453 (1998). https://doi.org/10.1080/00908319808970070 [Google Scholar]
- S. Koohi-Fayegh and M. A. Rosen, J, A review of energy storage types, applications and recent developments. Energy Storage, 27, 101047 (2020). https://doi.org/10.1016/j.est.2019.101047 [Google Scholar]
- M. A. Rosen, N. Pedinelli, and I. Dincer, Energy and exergy analyses of cold thermal storage systems. Int. J. Energy Res., 23, 1029–1038 (1999). https://doi.org/10.1002/(SICI)1099- 114X(19991010)23:12<1029::AID- ER538>3.0.CO;2-C [Google Scholar]
- Z. Kang, R. Wang, X. Zhou, and G. Feng, Research Status of Ice-storage Air-conditioning System. Procedia Eng., 205, 1741–1747 (2017). https://doi.org/10.1016/j.proeng.2017.10.020 [Google Scholar]
- P. W. Egolf, A. Kitanovski, D. Ata-Caesar, D. Vuarnoz, and F. Meili, Cold storage with ice slurries. Int. J. Energy Res., 32, 187–203 (2008). https://doi.org/10.1002/er.1340 [Google Scholar]
- G. Li, Y. Hwang, and R. Radermacher, Review of cold storage materials for air conditioning application. Int. J. Refrig., 35, 2053–2077 (2012). https://doi.org/10.1016/j.ijrefrig.2012.06.003 [Google Scholar]
- S. Okawa, A. Saito, and T. Harada, Experimental study on the effect of the electric filed on the freezing of the supercooled water. Trans. Jpn. Soc. Refrig. Air Cond. Eng., 14, 47–55 (2011) [Google Scholar]
- M. Tanino and Y. Kozawa, Ice-water two-phase flow behavior in ice heat storage systems. Int. J. Refrig., 24, 639–651 (2001). https://doi.org/10.1016/S0140-7007(00)00085-2 [Google Scholar]
- S. Okawa, A. Saito, and H. Suto, The experimental study on freezing of supercooled water using metallic surface. Int. J. Refrig., 25, 514–520 (2002). https://doi.org/10.1016/S0140-7007(01)00038-X [Google Scholar]
- J. Castaing-Lasvignottes, T. David, J.-P. Bédécarrats, and F. Strub, Dynamic modelling and experimental study of an ice generator heat exchanger using supercooled water. Energy Convers. Manag., 47, 3644–3651 (2006). https://doi.org/10.1016/j.enconman.2006.03.019 [Google Scholar]
- C. Zhang, L. Yang, W. Lin, J. Wei, and F. Guo, Performance Enhancement and Life-Cycle Cost Savings of Supercooled Water Ice Slurry Generation Systems Using Heat Regeneration. Sustainability, 14, 3836 (2022). https://doi.org/10.3390/su14073836 [Google Scholar]
- W. Wang, C. Liang, F. Zha, H. Wang, W. Shi, Z. Cui, K. Zhang, H. Jia, J. Li, and X. Li, Air conditioning system with dual-temperature chilled water for air grading treatment in data centers. Energy Build., 290, 113073 (2023). https://doi.org/10.1016/j.enbuild.2023.113073 [Google Scholar]
- C. Liang, Y. Wang, and X. Li, Energy-efficient air conditioning system using a three-fluid heat exchanger for simultaneous temperature and humidity control. Energy Convers. Manag., 270, 116236 (2022). https://doi.org/10.1016/j.enconman.2022.116236 [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.

