Open Access
| Issue |
E3S Web Conf.
Volume 689, 2026
14th International Symposium on Heating, Ventilation, and Air Conditioning (ISHVAC 2025)
|
|
|---|---|---|
| Article Number | 05004 | |
| Number of page(s) | 7 | |
| Section | Indoor Air Quality and Ventilation | |
| DOI | https://doi.org/10.1051/e3sconf/202668905004 | |
| Published online | 21 January 2026 | |
- A. Sarker, S. Chahardoli, A. Bhattacharya, Numerical and Statistical Analysis of Mixing Ventilation (MV) and Displacement Ventilation (DV) Systems on the Quantification of Airborne Infection Risk in Indoor Environments, ASHRAE Transactions, 131(Pt2), pp. 579–587, (2025), https://doi.org/10.63044/s25num66 [Google Scholar]
- W. Zhao, M.F. Ejaz, , S. Kilpeläinen, J. Jokisalo, R. Kosonen, The potential of local exhaust combined with mixing and displacement ventilation systems to mitigate COVID-19 transmission risks, Building and Environment, 266, 112076, (2024), https://doi.org/10.1016/j.buildenv.2024.112076 [Google Scholar]
- O. Osman, M. Madi, E.L. Ntantis, K.Y. Kabalan, Displacement ventilation to avoid COVID-19 transmission through offices, Computational Particle Mechanics, 10(3), pp. 355–368, (2023), https://doi.org/10.1007/s40571-022-00492-8 [Google Scholar]
- B.E. Yuce, A. Aganovic, P.V. Nielsen, P. Wargocki, Analysis of parameters influencing pathogen concentration in a room with displacement ventilation using computational fluid dynamics and Taguchi methods, Journal of Building Engineering, 80, 108002, (2023), https://doi.org/10.1016/j.jobe.2023.108002 [Google Scholar]
- Yasushi KONDO, Shunsuke OGITA, Hajime YOSHINO, Miwako FUJITA, STUDY ON DISPLACEMENT VENTILATION SYSTEM IN AN ELECTRICAL COMMERCIAL KITCHEN, Journal of Environmental Engineering (Transactions of AIJ), Volume 77, Issue 676, (2012), https://doi.org/10.3130/aije.77.481 [Google Scholar]
- Y. Honda, T. Yamanaka, H. Kotani, Y. Momoi, K. Sagara, D. Tatsumi, S. Ueda, T. Maeda, Ventilation Design of Sickroom by Low Velocity Fabric Air Diffuser on Ceiling, Proceedings of the 11th International Conference on Industrial Ventilation (Ventilation 2015) Volume Ⅱ,pp.990-999 , (2015) [Google Scholar]
- T. Yamanaka, C. Narae, T. Kobayashi, N Kobayashi, S. Ishikawa, Y. Nagai, N. Matsui, T. Okamoto, T. Arakawa, Y. Yamoto and S. Otaka, Ventilation Effectiveness of Ceiling-Supplied Displacement Ventilation System for Office Room (Part 1) Comparison of Temperature and Contaminant Concentration Distributions under Different Ventilation Systems using Full-Scale Experimental Chamber, in Proceedings of Roomvent 2024, 22-25 April 2024, Stockholm, Sweden (2024) [Google Scholar]
- M. Kuranaga, T. Yamanaka, C. Narae, T. Kobayashi, N Kobayashi, S. Ishikawa, Y. Nagai, N. Matsui, T. Okamoto, T. Arakawa, Y. Yamoto and S. Otaka, Ventilation Effectiveness of Ceiling- Supplied Displacement Ventilation System for Office Room (Part 2) A Parametric Study on the Indoor Environment Examined by CFD Analysis, in Proceedings of Roomvent 2024, 22-25 April 2024, Stockholm, Sweden (2024) [Google Scholar]
- M. Bivolarova, J. Ondráček, A.K. Melikov and V. Ždímal, A comparison between tracer gas and aerosol particles distribution indoors: the impact of ventilation rate, interaction of airflows, and presence of objects, Indoor Air, 27, (6), 1201–1212, (2017), https://doi.org/10.1111/ina.12388 [Google Scholar]
- P.V. Nielsen, Displacement Ventilation -theory and design, Aalborg University, 14 - 17, (1993) [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.