Issue |
E3S Web Conf.
Volume 124, 2019
International Scientific and Technical Conference Smart Energy Systems 2019 (SES-2019)
|
|
---|---|---|
Article Number | 05003 | |
Number of page(s) | 6 | |
Section | Additional papers | |
DOI | https://doi.org/10.1051/e3sconf/201912405003 | |
Published online | 10 February 2020 |
Development of a method for determining the location of a single line-to-ground fault of an overhead power line with voltage of 6(10) kV considering climatic factors
1
Industrial University of Tyumen, 38, Volodarsky Street, Tyumen, 625000, Russia
2
Nizhnevartovsk State University, 56, Lenin Street, Nizhnevartovsk, 628600, Russia
* Corresponding author: sidorovsv@tyuiu.ru
One of the main causes of the high accidents and outages rate in 6(10)-kV distributed power supply systems of oil well clusters is damage to overhead power lines due to single line-to-ground faults. Widely conducted studies to locate a single line-to-ground fault have established a correlation between the accuracy of determination and a large number of changing factors, such as operating mode parameters, overhead power line parameters, type of damage, transition resistance, soil resistance, and others. Rationing of technical means for determining the location of a single line-to-ground fault by instrumental errors without taking into account the methodological component translates into the error in locating the damage up to 30%. Thus, relevant research is aimed at determining the primary parameters of power lines and minimizing the methodological error in determining the location of damaged power lines, considering climatic factors. The study takes into account the basic physical processes of propagation of an electromagnetic wave in the power line. The main principles of the theory of electrical circuits and the electromagnetic field and MATLAB Simulink package algorithms are used. As part of the study, a technique has been developed that allows determining the distance from 6(10)/0.4-kV substations to a single line-to-ground fault location in distribution networks of oil well clusters taking into account climatic factors. A simulation model of a 10-kV distribution network supplying oil well clusters was developed in MATLAB Simulink, taking into account the dependence of the primary power line parameters on climatic factors and soil resistivity.
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.