Coverage of energy for the preparation of hot tap water by installing solar collectors in a singlefamily building
Rzeszow University of Technology, Department of Building Engineering, Al. Powstańców Warszawy 12, 35-959 Rzeszow, Poland
* Corresponding author: olekstar@prz.edu.pl
The paper presents the results of experimental studies on the consumption of hot water, energy obtained from the solar installation in the production process and the degree of coverage of usable and final energy with solar collectors. Thermal energy measurements from solar collectors cover the measurement period from 2011 to 2017. During this period, the annual final energy obtained from solar collectors ranged from 1033-1576 kWh. Monthly and annual demand for usable and final energy for the demand for hot water is presented depending on the amount of hot water used. Monthly actual consumption of hot water in the measurement period ranged from 3.57-9.16 m3. During this period, the number of residents has changed from 3 to 5 people. Annual coverage of energy useful for heat and energy by solar panels in the years 2011-2017 fluctuated from 38.0%-63.9% and 25.2%-42.3% for final energy. Monthly energy coverage ranged from 5.5% to over 100%. Covering energy above 100% in practice means getting a higher temperature of hot water in the outlet valve than expected.
© The Authors, published by EDP Sciences, 2018
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.