Issue |
E3S Web Conf.
Volume 97, 2019
XXII International Scientific Conference “Construction the Formation of Living Environment” (FORM-2019)
|
|
---|---|---|
Article Number | 05018 | |
Number of page(s) | 8 | |
Section | Hydrotechnical Construction and Melioration | |
DOI | https://doi.org/10.1051/e3sconf/20199705018 | |
Published online | 29 May 2019 |
Pre-design inspection of the long-term operation lock
1
Moscow State University of Civil Engineering, Yaroslavskoe shosse, 26, Moscow, 129337, Russia
2
Inzhstrojjservis, St. Staroslobodskaya, 3, office 7, Moscow, 107113, Russia
* Corresponding author: lfrishter@mail.ru
For hydraulic structures of long-term operation, assessments of operating life, limit states and safety of structures are required. The design of reconstruction, restoration of functional parameters of structures is preceded by pre-design inspections of the structure. The relevance of pre-design inspections is the need to assess the characteristics of technical and operating state of the structure, to describe reasons for deviations from design parameters of operation, to obtain recommendations to justify the design of reconstruction, restoration or repair of structures. This article presents the results of a pre-design inspection of a high-pressure lock on the Ufa River. An analysis of the complex of effects on the stress-strain state of the structure, static calculation of the lock chamber wall is carried out considering design changes during the operation period – installation of additional buttresses, vibrodynamic inspection and calculation. The obtained calculation results are compared with data of instrumentation equipment. The purpose of the inspection is to obtain a preliminary design assessment of technical state of the hydraulic structure – lock, including an assessment of the possibility of further operation. The practical significance of the paper is determined by the fact that the results obtained can serve as baseline data for a design of reconstruction, restoration of a hydraulic structure and recommendations for ensuring its long-term safe operation.
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.