Human-Oriented Design of an Indoor Thermal Environment
1 Waseda University, Department of Architecture, Tokyo, Japan
2 Kogakuin University, Department of Architecture, Tokyo, Japan
* Corresponding author: m.ukai@kurenai.waseda.ac.jp
In this study, an initial survey of clothing insulation and changes in the metabolic rate of individuals in office spaces was performed to establish the distribution of room temperatures at which individuals perceived a neutral thermal sensation. Subsequently, the indoor thermal environment in four offices was surveyed during the summer with different air-conditioning systems to determine the thermal environment stability in each case. The results revealed that for the required temperature, there was a noticeable difference between the average and most frequent values. Moreover, it was determined that the required temperature distribution is not normal, but rather, it is skewed to the low-temperature side. In addition, the radiant air-conditioning system was found to generate a narrow distribution of the equivalent temperature and hence, facilitated a more uniform thermal environment compared to a convective (multi-unit) air-conditioning system. Therefore, in buildings with convective air-conditioning systems, even if the planar average thermal environment is categorized as comfortable, it may be possible that workers who are sensitive to the cold or heat will complain of discomfort more frequently than those in buildings with radiant air-conditioning systems because the probability of workers sitting in cold- or hot-spot areas is higher in the former case.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.