Quicker Measurement of Walls’ Thermal Resistance Following an Extension to ISO 9869 Average Method
OTB: Research for the Built Environment, Delft University of Technology, Julianalaan 134, Delft, the Netherlands
* Corresponding author: A.Rasooli@tudelft.nl
Determination of the thermo-physical characteristics of the buildings’ components is crucial to illustrate their thermal behavior and therefore their energy consumption. Along the same line, accurate determination of the thermal resistance of the building walls falls into one the most important targets. Following the difference between in-lab, and on site thermal performance of walls, in-situ measurements have been highly recommended. The most well-known practice for in-situ measurement of walls’ thermal resistance is the Average Method of ISO 9869, using one heat flux meter and two thermocouples. The method, in comparison with other existing methods is quite straight-forward and therefore, is applied widely in large scale. Despite its simplicity, this method usually needs a relatively long time to reach an acceptable result. The current paper deals with a modification to the ISO 9869 method, making it in many situations much quicker than its original state. Through simulation of walls of different typologies, it is shown in which cases the measurement period becomes longer than expected. It is demonstrated how the addition of a heat flux meter to the aforementioned equipment can lead to a much quicker achievement of the thermal resistance, following the rest of the instructions of the standard method.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.