Design optimization of a building attached sunspace through experimental monitoring and dynamic modelling
1 Department of Architecture and Design, University of Genoa, 16123 Genoa, Italy
2 Faculty of Technology, Linnaeus University, SE-35195 Växjö, Sweden
* Corresponding author: ambrose.dodoo@lnu.se
In Europe, buildings are responsible for 40% of the energy consumption and 36% of the CO2 emissions. Space heating largely contributes to these energy and climate impacts. Passive solar heating systems, as sunspaces, can contribute to increase solar heat gains, reducing space heating energy demand and the related use of fossil fuels. Careful design and local climatic considerations are essential to optimize the performance of sunspaces. In this study experimental field monitoring, dynamic modelling and steady-state methods are applied to analyse the thermal behaviour of an attached sunspace in an Italian existing building, as well as its potential contribution to the building’s energy balance. Design modifications for improved thermal performance of the sunspace are investigated. The results show overall agreement between the dynamic modellings and experimental monitoring of the sunspace and indicate that the sunspace’s indoor air temperature and hence solar energy gains are significantly increased with the design modifications, in contrast to the existing configuration. Maximum temperatures between 44 and 48 °C were observed for the existing and a modified alternative of the analysed sunspace. The dynamic simulation model and design modifications presented in this study can serve as basis for assessment and optimal configurations of sunspaces in their design stage.
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.