On the importance of desiccant during the determination of water vapor permeability of permeable insulation material
Univ Bretagne Sud, UMR CNRS 6027, IRDL, 56100 Lorient, France
* Corresponding author: thibaut.colinart@univ-ubs.fr
Water vapor permeability of building materials is usually measured using dry cup test according to the ISO 12572 standard. For this test, suitable adsorbing desiccant should be used to provide stable low vapor pressure conditions within the cup and, thus, to ensure the good accuracy of the measurement. In this work, different adsorbing desiccants mentioned in the ISO 12572 standard are tested for measurements performed on wood fiber insulation. For each experiment, relative humidity is monitored inside the dry cup. The results indicate that 0 %RH is not reached inside the dry cup and boundary condition is not always stable for highly permeable construction materials, depending on the adsorbing desiccants. The impact of these observation is evaluated on the determination of water vapor diffusion resistance factor and compared to other sources of uncertainties.
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.