Determination of Generator Capability Curve using Modified-Single Machine to Infinite Bus (M-SMIB) System Approach
1
Electrical Engineering Department, Akademi Teknik Pembangunan Nasional, Jl. Taman Gembira Barat No.14, Banjarbaru, South Kalimantan 70714, Indonesia
2
Electrical Engineering Department, Institut Teknologi Nasional, Jl. Raya Karanglo Km. 2, Malang, East Java, 65145, Indonesia
3
Hiroshima University, 1-4-1 Kagamiyama, Higashihiroshima 739-8527, Japan
* Corresponding author: habsyi.sila@gmail.com
The capability curve for each generator unit is usually provided by the generator manufacturer. But in practice, the generator can reach its maximum generation limit before reaching the maximum limit on the generator capability curve provided by the generator manufacturer. This might occur because of the load location is far from the generator or the varying of the loading value so that the maximum generation limit is smaller than the value given on the generator capability curve of the manufacturer. In this paper, the generator capability curve is determined using the Modified Single Machine to Infinite Bus (M-SMIB) system approach to determine the maximum generation limit every time there is a change in loading or change in the load location. After the maximum generation limit of each unit generator is known, the generator capability curve that is always in accordance with the real time situation can be formed. Thus, the operation limit of each generator can be recognized, determine the appropriate protection system setting and can prevent the electric power system disturbance. This method will be applied to generator units in the four bus IEEE system with two generators.
Key words: Maximum generation limit / operation generator limit / protection system setting
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.