Issue |
E3S Web Conf.
Volume 286, 2021
10th International Conference on Thermal Equipments, Renewable Energy and Rural Development (TE-RE-RD 2021)
|
|
---|---|---|
Article Number | 01008 | |
Number of page(s) | 9 | |
Section | Thermal Equipments and Processes | |
DOI | https://doi.org/10.1051/e3sconf/202128601008 | |
Published online | 12 July 2021 |
Experimental COP evaluation of a 65-litre household refrigerator running with R600a
1 Dept. of Applied Thermodynamics, Engines, Thermal and Refrigeration Equipment, University Politehnica of Bucharest, Romania
2 University of Babylon, Iraq
3 Al-Furat Al-Awsat Technical University, Technical College Najaf, Iraq
4 University of Technology, Iraq
5 Candida Oancea Institute, Polytechnic University of Bucharest, Spl. Independentei 313, Bucharest 060042, Romania
* Corresponding author: valentin.apostol@magr.ro
A household refrigerator is a major energy consumer in all homes. The paper aims to evaluate based, on experimental data, the COP of a 65-liter household refrigerator operating with R600a. The main components and instrumentation of the experimental setup are presented. A mathematical model based on the energy balance of the refrigerated enclosure is developed in order to evaluate the COP. Three experimental data sets have been obtained in quasi-steady-state operating conditions. The results point out that the compressor power absorbed from the grid was 60 [W]. The maximum value for the cooling capacity is 81.73 W while the minimum value is 80.24 W. In terms of COP, the maximum value obtained is 1.362, while the minimum one is 1.337. The COP values obtained in the present study are in good agreement with the ones displayed by the manufacturer in the compressor datasheet. Future development is discussed.
Key words: COP / R600a / household refrigerator
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.