Issue |
E3S Web Conf.
Volume 288, 2021
International Symposium “Sustainable Energy and Power Engineering 2021” (SUSE-2021)
|
|
---|---|---|
Article Number | 01077 | |
Number of page(s) | 8 | |
DOI | https://doi.org/10.1051/e3sconf/202128801077 | |
Published online | 14 July 2021 |
Problems of Insulation Diagnostics of Power Equipment by the Method of Partial Discharges
Kazan State Power Engineering University, Kazan, Russia
* Corresponding author: usachev.ae@kgeu.ru
Target. High information value and reliability of diagnostics of isolation by partial discharges. Methods. Simulation of PD in Multisim and calculation of electrical fields of insulation defects by finite element method in the program ComSol. Results. A strong influence of the power supply on the value of voltage surge in case of emergency has been established. The method of adjustment of this influence is proposed. It was found that the oscillatory form of the PD is mainly determined not by the parameters of the insulation defect, but by the parameters of the energy object in which this defect is observed. Method for separation of aperiodic signal of PD from oscillatory component of system transient process in PD is proposed. It is shown that in operating turbogenerators and power transformers the unambiguous connection between the phase of PD occurrence and the voltage of PD occurrence is broken. Method of determination of PD occurrence place in slot part of turbogenerators is proposed. It is shown that in order to increase the reliability of comparing PD in polymer insulation of power cables of different voltage classes and geometric dimensions, when calibrating the measuring system, it is necessary to take into account the speed of propagation of the PD pulse through the cable and the capacity of the cable length unit. The concept of a corrective coefficient for calibration has been introduced and a method for determining it has been proposed. Conclusions. Taking into account the differences in PD parameters in real objects of the electric power industry, proposed in the article, from the parameters obtained in the standard laboratory model of the PD should increase the information and reliability of the PD method, as well as make it possible to conduct a comparative analysis of the results obtained under various observation conditions.
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.