An Experimental Investigation on Indoor Air Pressure Performance of Multi-compartment Pharmacy Cleanroom under Local Fume Hood Operating Scenario
1 Institute of Artificial Environment and Energy Application, Beijing Union University, 100023 Beijing, China
2 Beijing Key Laboratory of Biomass Waste Resource Utilization, Beijing Union University, 100023 Beijing, China
* Corresponding author: maxiaojun@buu.edu.cn
The control of indoor air pressure is very important in cleanroom operation, because of its sensitiveness of the risks from contaminants dispersion. Especially in pharmaceutical cleanrooms, since there always exist multiple compartments, the parametric stability of indoor air pressure is the key-point of operation control. When a fume hood in cleanroom running, the exhaust air volume changes greatly and then cause indoor pressure oscillating. Meanwhile, this scenario of fume hood running is often occurred because of manufacturing process need. However, the performance pattern of pressure is not clear when fume hood switches on or off. Therefore, the control strategy might be inefficient and even invalid. In this paper, the performance of indoor air pressure of multi-compartment cleanrooms under fume hood operating scenario is measured and analysed by experimental investigation method. The works of this paper might help understanding the performance of pressure variation in cleanrooms when disturbances occur and change. And the conclusions of this paper could be references for the design and operation strategies of multi-compartment cleanrooms.
© The Authors, published by EDP Sciences, 2022
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.