Design and analysis of a window-integrated passive system (WIPS) with the use of solar heat gains
1 School of Civil, Environmental and Architectural Engineering, Korea University, Seoul, Republic of Korea
2 School of Architecture, University of Ulsan, Ulsan, Republic of Korea
* Corresponding author: yeonsookheo@korea.ac.kr
As one of the passive building design strategies to decrease ventilation energy consumption, several window-integrated passive systems (WIPS) have been developed and implemented into buildings. This study proposed a new WIPS inspired by a double skin façade (DSF) design that provides pre-heating and ventilation by utilizing solar heat gains collected in the air cavities. The performance of the proposed WIPS was analyzed and developed based on different design parameters such as material, width, height, shape, depth, and opening area, for the wintertime in Seoul, Korea. Furthermore, the computational fluid dynamics model, Fluent 2021 R2 with the RNG k-epsilon turbulence model, was used for the simulation. To focus on the buoyancy effect occurring in the air cavities, the influence of wind was excluded from the CFD modelling and analysis. Therefore, 0 Pa pressure differences between the inlet and outlet of the room were applied. The results showed that the buoyancy effect increased in the WIPS with a wider and higher inflow cavity than a case with narrower and shorter cavity, also utilizing glass material for the cavity surfaces exposed to the outside resulted in absorbing more solar radiation and more buoyancy effect. Moreover, the converged shape cavity increased the volume flow rate of the cavity due to the increased air velocity from the Venturi effect. Overall, all design parameters can impact the performance of WIPS either by hindering or assisting the airflow of the WIPS.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.