Issue |
E3S Web Conf.
Volume 399, 2023
International Conference on Newer Engineering Concepts and Technology (ICONNECT-2023)
|
|
---|---|---|
Article Number | 06004 | |
Number of page(s) | 11 | |
Section | Thermal | |
DOI | https://doi.org/10.1051/e3sconf/202339906004 | |
Published online | 12 July 2023 |
Experimental investigation on split type window Air conditioner using HFC and HC mixture as ecofriendly refrigerant alternate to HCFC-22
1 Research Scholar, Mechanical Engineering, Vels Institute of Science, Technology & Advanced Studies, Chennai
2 Mechanical Engineering, Vels Institute of Science, Technology & Advanced Studies, Chennai
3 Mechanical Engineering, Bannari Amman Institute of Technology, Sathyamangalam, 638401, India
4 Mechanical Engineering, Nadar Saraswathi College of Engineering and Technology, Theni
* Corresponding author: parthibana83@gmail.com
This paper reports on an experimental study evaluating a window air conditioner's performance when R152a/R290/R600/R600a refrigerant mixture (by various mass percentages) is used as a possible alternative to R-22. Alternative refrigerants are local, cheap, and environmentally friendly. Unmodified R-22 window AC was charged with R152a/R290/R600/R600a. During the experiment, parameters such as coefficient of performance, refrigeration effect, pressure ratio, compressor discharge temperature, refrigerant mass flow rate, and compressor power are analyzed. The present work shows that R152a-15%/R290-15%/R600-35%/R600a-35% is the best-performing alternative refrigerant. Proposed blends and R22's performance were compared.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.