  1. European Council Conclusions on 2030 Climate and Energy Policy Framework, SN 79/14 (2014) [Google Scholar]
  2. B. Bøhm, Production and distribution of domestic hot water in selected Danish apartment buildings and institutions. Analysis of consumption, energy efficiency and the significance for energy design requirements of buildings, Energy Convers. Manag. 67 152–159 (2013) [Google Scholar]
  3. Regulation of the Minister of Infrastructure on the technical conditions that should be met by buildings and their location of April 12, 2002, Journal of Laws 75, item 690 (2002) [Google Scholar]
  4. J.E. Thorsen, Analysis on flat station concept, in: 12th Int. Symp. Dist. Heat. Cool., Tallinn, Estonia (2010) [Google Scholar]
  5. A. McNabb, G.J. Weir, Heat losses from an insulated pipe, Journal of Mathematical Analysis and Applications 77, 270–277 (1980) [CrossRef] [Google Scholar]
  6. M. Čarnogurská, M. Příhoda, M. Puškár, M. Fabian, R. Dobáková, M. Kubík, Measurement and mathematical modelling of heat loss in the pipe systems of a central heat distribution network, Meas. J. Int. Meas. Confed. 94 806–811 (2016) [CrossRef] [Google Scholar]
  7. Z.K. Morvay, D.D. Gvozdenac, Applied Industrial Energy and Environmental Management, (Wiley-IEEE Press 2008) [CrossRef] [Google Scholar]
  8. S. Mańkowski, Projektowanie ciepłej wody użytkowej, (ARKADY Publishing House, 1981) [Google Scholar]
  9. E. Nowakowski, Termostatyczne zawory regulacyjne w obiegu cyrkulacyjnym instalacji ciepłej wody, Rynek Instal. 4, 51 (2009) [Google Scholar]
  10. W. Szaflik, Współpraca cyrkulacyjnych podpionowych zaworów termoregulacyjnych z instalacją ciepłej wody i ich dobór, Ciepłownictwo, Ogrzewnictwo, Wentylacja 12, 16–18 (2007) [Google Scholar]
  11. Danfoss, Multifunctional Thermostatic Circulation Valve MTCV, (2016) [Google Scholar]
  12. Oventrop, “Aquastrom C” Double regulating and commissioning valves for circulation pipes in potable water installations (2016) [Google Scholar]
  13. I. Polarczyk, M. Fijewski, Impact of the circulation system on domestic hot water consumption, in: E3S Web Conf., 22 00136 (2017) [Google Scholar]
  14. PN-B-02421:2000 Heating and district heating - Heat insulation of pipelines, valves and equipment - Specification and reception tests (2000) [Google Scholar]
  15. R Core Team, R: A Language and Environment for Statistical Computing, R Found. Stat. Comput. Vienna, Austria (2017) [Google Scholar]
  16. H. Wickham, ggplot2 Elegant Graphics for Data Analysis (2009) [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.