  1. Aleksandrov G.N. The design of EHV transmission lines. Leningrad, Energoatomizdat Publ., 1993. 560 p. [Google Scholar]
  2. D'iakov A.F. The electric networks of EHV and UHV UES of Russia. Theoretical and practical issues. Moscow, NTF "Energoprogress" Corporation "EEEK" Publ., in 3 vols., 2012. 696 p. [Google Scholar]
  3. A. s. 1056341 USSR. MKI3 H02H 3/06. A device for monitoring the state of a phase of a power line with shunt reactors disconnected in the cycle of single-phase automatic reclosing / M.L. Levinstein, M.I. Khoroshev, A.F. Kalinichenko, Yu. I. Lyskov // Discovery. Inventions 1983 No. 46. [Google Scholar]
  4. A. s. 1092642 USSR, MKM3 H02H 3/06. A method for controlling the disappearance of a short circuit on a disconnected power line and a device for its implementation / V. A. Ilyin, B. And Kovalev, M. And Khoroshev, Yu.I. Lyskov // Discoveries. Inventions 1984. No. 18. [Google Scholar]
  5. A. s. 632023 USSR. MKI3 H02H 3/06. The method of single-phase automatic reclosing of the power line / V. N. Sobolev, V.F. Lachugin, Yu. I. Lyskov, V.G. Kagan // Discovery. Inventions 1978, No. 41. [Google Scholar]
  6. A. s. 740108 USSR, MKM3 H02H 3/06 11/00. A method for monitoring the state of a power line phase disconnected in a single-phase automatic reclosing of a power line with shunt and compensation reactors / N. N. Belyakov, V. S. Pashkes, K. V. Hoscian // Discovery. Inventions 1981.№26. [Google Scholar]
  7. S.P. Websper, A.T, Johns, R.K. Aggarwal. And R.W. Dunn «An investigation into breaker reclosure strategy for adaptive single pole autoreclosing», IEE Proc.- Gener. Transm. Distrib., vol.142, no.6, pp.601-607, Nov.1994. [CrossRef] [Google Scholar]
  8. S. Ahn, Ch.Kim, R.K. Aggarwal. and A.T, Johns, «An alternative approach to adaptive single pole autoreclosing in high voltage transmission systems based on variable dead time control», IEEE Trans. Power Delivery, vol.16, no.4, pp.676 – 686, Oct. 2001. [Google Scholar]
  9. Krasil'nikova T.G., Dzhononaev S.G. Comparative analysis of ways to eliminate unstable single-phase short circuits in non-transposed lines of EHV and UHV// Electricity . 2017.no. 11, pp. 22–29. [Google Scholar]
  10. Krasil'nikova T.G., Dzhononaev S.G. Effect of duration of pause SPAR on the throughput of the transmission in condition for dynamic stability.// Scientific Bulletin of Novosibirsk state technical University. 2017. no. 2 (67), pp.163–176. [CrossRef] [Google Scholar]
  11. Dzhononayev S.G. Elimination of unstable Single- Phase Short-Circuits in transposed lines in the SPAR cycle using automatic phase shunting // Scientific Bulletin of Novosibirsk state technical University. 2018. no. 3 (72), pp.157–174. [Google Scholar]